甜菜浆

直接从储存坑中输送甜菜浆

即使在高负载下,NEMO® BT 立式泵也能降低材料磨损 

在沼气生产中,尽管负载较大,但输送甜菜期间,NEMO®BT立式泵的材料磨损仍然较低。

甜菜,尤其是转基因甜菜和特殊培育的能源甜菜,正变得越来越受欢迎。

个案咨询

立即获得个性化服务!

查看更多
Beet Pulp, NETZSCH, Pumps, Systems

背景介绍

甜菜储存在筒仓或青贮管中既复杂又昂贵。在铝箔内衬的坑中收集甜菜浆是一种相对简单且成本效益高的替代方法。

接受挑战

在特定应用中,每小时约10 m³的甜菜丁被运输到发酵罐。然而,由于在储存坑表面形成了半固态氧化层,因此高粘度基质必须从这层浮渣下面抽出。在水箱或浮筒边缘水平安装的泵无法提高高吸入性能。另一方面挑战是甜菜浆的低pH值和基质体积高达10%的高磨蚀性含沙量。

10

基质体积中10%的磨蚀性含沙量 

接受营销 Cookie 以观看视频。

With the NEMO® BY progressing cavity pump in FSIP® design with xLC® stator adjustment system you can reduce maintenance time.

NEMO® BT immersible pump conveys beet pulp with minor wear

A NEMO® BT immersible pump was therefore installed in the system, which is otherwise also used for emptying tanks and pits of viscous to non-free-flowing media, such as crude oil. The NETZSCH developers installed a stator made of the highly resistant elastomer NEMOLAST® and a chrome-plated stainless steel rotor. In addition, it is sufficient to operate the pump at a moderate speed of 190 rpm, which reduces abrasion. 

完美解决

为此,安装了NEMO®BT立式泵。这些也用于其他地方,用于将原油等高粘度介质从储罐和矿坑中排出。因此,耐驰的开发人员为此安装了一个由高强度NEMOLAST®橡胶制成的定子和一个耐磨转子。此外,泵以约190 rpm的适当转速运行,延长了其使用寿命。因此,尽管存在高应力,材料磨损仍然可以保持在较低水平。

NEMO®BT立式泵

介质:甜菜浆
流量:10m3/h
转速:190rpm
压力:24bar
深度:最大10米

NEMO® BT Immersible Pumps With Bracket or Flanges, NETZSCH, Pumps, Systems