15.07.2024

Menghidupkan kembali Webinar: Meningkatkan Efisiensi dalam Industri Kimia

Philipp Nübl membahas pompa berpasangan magnetis yang inovatif untuk industri kimia dalam webinar yang mempromosikan keselamatan dan efisiensi.

Pada saat biaya meningkat dan proses yang semakin kompleks, peningkatan efisiensi dan keandalan proses sangat penting. Oleh karena itu, NETZSCH Pumps & Systems telah mengembangkan lebih lanjut teknologi yang telah terbukti dari pompa rongga yang sedang berkembang dan melengkapinya dengan kopling magnetik untuk memenuhi tantangan ini.

The chemical industry requires continuous innovation as well as the highest safety and efficiency standards. Downtimes and leaks cause considerable costs and risks. The NEMO® MY magnetically coupled pump offers a cost-effective solution to avoid such costly incidents.

Menghidupkan Kembali Webinar Pompa Berpasangan Magnetis

Dapatkan rekaman gratis Anda sekarang dan
menghemat uang di masa depan

minta sekarang

Profitabilitas dan efisiensi yang unggul

Progressing cavity pumps, which typically operate at 200 or 300 rpm, can now be designed as a smaller, lighter and more economical unit thanks to the reduction in the complexity of the magnetic coupling and the adaptation to NETZSCH progressing cavity pumps. The completely hermetically sealed design prevents the escape of hazardous liquids or vapours. This ensures the safety of your employees and your plant and creates a clean working environment, reducing your risks and costs. These pumps, specially developed for slurries, can pump products with up to 20,000 cps viscosities. The NETZSCH magnetic coupling allows you to utilise the advantages of progressing cavity pumps in applications for which progressing cavity pumps could not previously be used. In addition, the magnetically coupled pump is less cost-intensive than a pump with a mechanical seal and requires no maintenance of the sealing system. Constant seal pressure and maintenance of the liquid level in the sealing system are not required, which further simplifies operation.

NETZSCH magnetically coupled pump design enables safe, efficient handling of aggressive liquids without leakage or maintenance.
The magnetically coupled pump from NETZSCH is hermetically sealed. This prevents aggressive, toxic or abrasive liquids and gases from escaping.

Solusi inovatif untuk bahan kimia

NETZSCH has created further development that, in contrast to conventional pumps with mechanical seals, does not require dynamic seals but only static seals. Curious? Don't hesitate to secure your recording of our webinar!

Share this article

AI Overview
An error occurred. Please try again.