20.05.2021

Sistem Pompa Perpindahan yang Tepat di Sektor Higienis

Rainer Gozzer membahas tentang pemilihan pompa higienis di kantor modern, dengan menekankan pada keahlian dalam industri pompa.

Tawaran ini sangat besar, dan pompa dibeli dengan cepat. Namun, disarankan untuk berhati-hati saat membeli agar tidak mengalami kebangkitan yang tidak menyenangkan setelahnya. Terutama di lingkungan yang higienis, memilih pompa yang salah dapat dengan cepat menyebabkan masalah dan biaya tinggi. Oleh karena itu, beberapa pertanyaan penting harus diklarifikasi terlebih dahulu.

The hygienic industry covers a wide range of applications. From yoghurt via fruit juice concentrate to insulin, everything is included. The consistency of the respective media also varies from almost water-like to highly viscous, sometimes even piecey. Since product safety is the top priority during the process, any contamination must also be excluded, and residue-free cleaning must be ensured. This makes the selection process for the right pump often very complex. To simplify the selection process, we have put together the most important questions for you together with our Business Field Manager, Food & Pharmaceuticals Rainer Gozzer:

1. Apa saja karakteristik media tersebut?

  • Viscosity (describes the flowability of a medium)
  • Shear sensitivity (negative change in media structure due to mechanical stress)
  • Particles (does the medium contain particles and, if so, in which size and consistency)
  • Abrasivity (to what extent does the medium have an abrasive effect and thus cause wear so that particular material combinations have to be used)

2. What is the structure of the pumped medium?

  • DM content (denotes the dry mass in a mixture of substances)
  • pH value (indicates how strongly a solution is basic or acidic)
  • Corrosivity (to what extent the medium reacts with the installed materials and thus causes harmful changes to them)

Konsultasi Khusus

Dapatkan konsultasi yang dipersonalisasi!

hubungi sekarang

3. What are the technical process requirements?

  • Operating temperature
  • Suction side conditions (free inlet guaranteed or suction required)
  • Pumping pressure
  • Operating time

4. What are the individual requirements?

  • Hygienic requirements
  • Customer possibilities for cleaning the pump (CIP system available?)
  • Installation space (how much space is available for the pump?)
  • Required flexibility in terms of flow rate ranges as well as requirements regarding shaft sealings

Once these questions have been answered, the next step is to select the suitable pump model.

Pompa rongga, multi sekrup, dan pompa lobus putar yang berkembang

The NETZSCHprogressing cavity pump model NEMO® is particularly suitable for lumpy media, which must remain in their original form. The decisive factors here are the large conveying chambers and the gap-free design. As a result, there is very little, if any, backflow only at higher conveying pressures. In comparison, the progressing cavity pump provides the best results in terms of shear. It is also ideally suited for highly viscous media, such as cream cheese. A forced feed can push the medium into the stator inlet opening for further transport. Using specially matched materials for the rotor/stator combination (hard rotor with soft stator), the progressing cavity pump technology offers the best results when conveying abrasive media. In addition, it enables low-pulsation and thus very precise conveying, making it ideal for dosing applications.

Compared to the progressing cavity pump, both the multi screw pump and the rotary lobe pump in the full-metal version can perform better in terms of operating temperature ranges. As a result, both are suitable for the so-called SIP process, a process in which the pump can be sterilized within the plant. Due to contactless conveying elements, rotary lobe and multi screw pumps offer high product safety with low wear. With the suitable shaft seal configuration, they are mainly insensitive to dry running. In addition, the NETZSCH TORNADO® rotary lobe pump and the NETZSCH NOTOS® multi screw pump offer a so-called Full Service in Place design, which enables simple and fast maintenance without removing the pump from the system. However, the two technologies do differ in some aspects.

The NOTOS® hygienic multi screw pump is characterized by very easy cleaning. Multi screw pumps can be operated at very high speeds. The cleaning medium can be conveyed through the pump very quickly, thus cleaning it efficiently. There is no need for an additional cleaning pump. The use of different pairs of spindles allows the application for different flow rate ranges. Screw pumps are also characterized by low-pulsation delivery and are thus also suitable for dosing applications.

Compared to the other two models, the compact design of the TORNADO® T.Sano® rotary lobe pump makes it ideal for systems with limited space. Its smooth design, surface-cooled or water-cooled motors, and lubricant-free synchronization of the rotary pistons make the pump predestined for use in cleanroom areas. Any contamination is excluded.

Sorotan pompa perpindahan positif

NEMO®Pompa higienis BH dalam desain blok yang ringkas

NETZSCH NEMO® Pompa higienis BH, ideal untuk media yang menggumpal, menampilkan desain yang kuat untuk tekanan pemompaan yang tinggi dan pengangkutan yang lembut.
  • Suitable for lumpy media
  • Gentle conveying / no shear
  • Gapless design
  • High suction capacity
  • Particularly robust with regard to abrasive media
  • High pumping pressures
  • Low pulsation

NOTOS®pompa sekrup kembar higienis 2NSH di FSIP®

Pompa lobus putar higienis NETZSCH dirancang untuk pengiriman media kental dengan denyut rendah yang tepat dan presisi dalam aplikasi higienis.
  • SIP compatible
  • Insensitive to dry running
  • Contactless pump elements
  • FSIP®
  • Very easy cleaning (no CIP pump required)
  • Modular design
  • Low pulsation

TORNADO®T.Sano® pompa lobus putar dengan permukaan yang halus

NETZSCH T.Sano pompa lobus putar yang dirancang untuk aplikasi higienis, menampilkan desain yang ringkas dan perawatan yang mudah.
  • SIP compatible
  • Insensitive to dry running
  • Contactless pump elements
  • FSIP®
  • Very easy cleaning (no CIP pump required)
  • Compact design
  • Lubricating oil free
  • Smooth design availiable
  • Surface- or water-cooled motor possible

In summary, choosing the right pump for the application is not that easy, and some things have to be considered. Making this process easier, our on-site experts will be happy to assist you with many years of expert knowledge to find the perfect solution for your application.