26.04.2022

Keuntungan dari Pompa progressing cavity NEMO® dengan desain FSIP®

Pompa progressing cavity NEMO® dengan desain FSIP® menampilkan fitur perawatan yang mudah dan konstruksi yang kuat untuk beragam aplikasi industri.

Ramah servis, inovatif, berkinerja tinggi: Pompa rongga progresif NEMO® yang dapat digunakan secara fleksibel dalam desainFSIP® menjamin penghematan biaya dan kapasitas secara simultan di hampir semua area aplikasi industri.

In addition to ease of maintenance and service, the NEMO® offers you numerous other advantages. We will show you the advantages of our progressing cavity pumps and how to benefit from them.

1. Keuntungan: FSIP® desain memungkinkan penggantian yang mudah

The innovative design of our progressing cavity pump offers you easy access to wearing parts and thus simplifies maintenance and service. This is made possible by the large inspection cover, which provides quick access to the inside of the pump. This saves you time and costs during maintenance. When changing the stator alone, the working time can be reduced by 66 percent. The cover is fixed with only five screws and thus allows you to open it without any problems, even without expensive special tools. All wearing parts can be changed in less than half the time.

Pompa progressing cavity NEMO® dengan desain FSIP®yang menampilkan perawatan yang mudah, konstruksi yang ringkas, dan kemampuan performa tinggi.
Menghemat hingga 66 persen waktu servis, dengan Pompa progressing cavity NEMO® dalam desain FSIP® memungkinkannya.

2. Keuntungan: Desain blok yang kuat dan ringkas

Another advantage of the NEMO® progressing cavity pump in FSIP® design is its compact block construction. This is particularly space-saving and allows you to install the pump in confined spaces. There is no need for an additional dismantling length, which is necessary to remove the rotor in a standard design. The robust construction of the NEMO® makes it particularly suitable for use under demanding conditions. Thin-flowing to viscous media in various industrial sectors present no problems. In addition, materials with and without solids can be conveyed smoothly. The NEMO® progressing cavity pump is a true all-rounder; even gentle pumping of sensitive media is no problem.

Konsultasi Khusus

Dapatkan konsultasi yang dipersonalisasi!

hubungi sekarang

3. Keuntungan: Penggantian rotor pompa yang mudah

Thanks to the inspection cover and the iFD-Stator® 2.0, you can easily remove the rotor-stator unit. The stator and rotor are then detached from each other outside the pump. If you remove another part of the power train in the pump lantern, our progressing cavity pump allows you to remove the connection shaft, the cartridge joint and the cartridge shaft seal. The rotor head connection makes it possible to change the rotor screw quickly and the rotor-side cartridge joint. This allows you to change the stator easily without removing the entire pump. This saves you time and money. The innovative design facilitates removal and helps when reassembling the elements. Thanks to the design, no adjustments have to be made. The pump housing acts as a support and orientation. The correct positioning is entirely automatic.

iFD-Stator® 2.0 oleh NETZSCH, dirancang untuk pemompaan yang efisien dan ramah lingkungan dalam aplikasi industri.
Jika kinerja, ekonomi dan kompatibilitas lingkungan sangat penting bagi Anda, iFD-Stator® 2.0 adalah pilihan yang tepat.

4. Keuntungan: Sambungan yang tepat untuk setiap aplikasi

We offer the right joint for every application and the most diverse operating conditions to maximise operational safety and life cycle cost savings. You can choose from the following joints:

  • B-universal pin joint
    The NEMO® B pin joint is the standard for industrial pumps due to its simple design and reliability. The joint is oil-filled and encapsulated by the NEMO® SM® sealing sleeve to achieve a long service life. In case of extremely high temperatures and pumping media that do not allow the use of elastomers, the joint can also be used without sealing. The joint consists of only a few components and can be easily dismantled for maintenance work.
  • V-bolt joint
    The NEMO® V-bolt joint works in the same way as the B-bolt joint. However, to increase the service life under difficult operating conditions, it also has hardened bushings pressed into the bores of the coupling rod and the rotor or drive shaft head. These can be easily replaced during maintenance work.
  • K-joint
    The patented K-joint was designed for highly high continuous loads in industrial applications. It is a cinematically precisely defined joint in which torque and axial forces are decoupled and transmitted via different machine elements. The joint is oil-lubricated and is hermetically sealed by two product- and lubricant-resistant sleeves. The additional oil filling between the two sleeves allows you to use it at ambient pressures of up to twelve-bar.
  • Z-pivot universal joint
    For effective flow rates or pressures, NEMO® industrial pumps are equipped with cinematically precisely defined journal universal joints in cartridge design. These are designed for highly high continuous loads, torques and axial forces. The joint is oil-lubricated and is hermetically sealed by two product- and lubricant-resistant sleeves.
Detail close-up dari a Pompa progressing cavity NEMO®mekanisme internal, menyoroti desainnya yang kuat untuk perawatan yang efisien.
Kami memiliki sambungan yang tepat untuk setiap aplikasi dan kondisi operasi yang paling beragam untuk memaksimalkan keselamatan operasional.

5. Keuntungan: Sistem konstruksi modular yang bervariasi

The NEMO® pump belongs to the group of positive displacement pumps. It consists of a rotor and a stationary stator in which the rotor rotates. A total of four different rotor/stator geometries are available. The exact external dimensions of the pumps and identical connections on the suction and discharge side for all four geometries result in a modular system. This means that you can make subsequent changes to the flow rate or pressure of already installed NEMO® pumps by replacing the rotor and stator.

6. Keuntungan: Dosis secara proporsional dengan kecepatan

Another advantage of the NEMO® progressing cavity pump is the speed-proportional dosing of almost any media. In addition to the continuous, pressure-stable, gentle and low-pulsation delivery, you can thus adjust the dosing accuracy in no time at all.

7. Keuntungan: FSIP® Konsep mudah dipasang kembali

Desain FSIP® dari pompa NEMO® kompatibel dengan seri BY dan SY. Konsep inovatif ini terdiri dari tiga tahap yang memungkinkan Anda untuk melakukan retrofit pompa yang sudah terpasang selangkah demi selangkah atau memilih tahap perluasan yang sesuai untuk instalasi baru sesuai dengan kebutuhan Anda.

  • FSIP.ready
    Pompa BY/SY dasar dalam desain casing yang inovatif dengan penutup inspeksi yang besar, dengan power train standar dan berbagai seal poros.
  • FSIP.advanced
    Pompa BY/SY dengan desain housing yang inovatif dengan penutup inspeksi yang besar, batang kopling terpisah, dan berbagai macam seal poros untuk penggantian rotor/stator dalam kondisi terpasang.
  • FSIP.pro
    Pompa BY / SY dalam desain rumah yang inovatif dengan penutup inspeksi yang besar, batang kopling terpisah, dan dua sambungan pin kartrid untuk "servis penuh di tempat", dan segel mekanis kerja tunggal.

Retrofit pompa rongga Anda yang sedang berkembang dengan konsep FSIP® yang inovatif sekarang atau dapatkan penawaran yang tidak mengikat dan hemat waktu dan uang di masa depan.