xLC® stator adjustment system untuk NEMO® pompa meningkatkan umur panjang dan efisiensi, mengurangi biaya perawatan dan operasional.
AKSESORI & PERALATAN OPSIONAL

xLC® stator adjustment system

Perpanjangan masa pakai layanan Pompa progressing cavity NEMO® lebih dari tiga kali lipat

Optimum performance and significantly extended service life for your progressing cavity pump: With the xLC® stator adjustment system, you can increase the service life of your pump by more than three times, especially in wear-intensive applications. The stator adjustment system is used to readjust the easy-to-replace, maintenance- and environmentally-friendly iFD-Stator® 2.0.

You can adjust the iFD-Stator® 2.0 in a simple and controlled way. Axial compression of the elastomer increases the preload, and the sealing line between the stator and rotor is readjusted. The pump performance is restored. Particularly with abrasive media, higher wear is noticeable, which causes the performance to drop more quickly. With the xLC® unit, your need for spare parts and maintenance is reduced, and you save costs. In addition to readjustment in case of wear, an integrated display always gives you information about the readjustment status of the stator and when a stator change is imminent. In this way, the tool offers more operational and planning reliability at a glance. The xLC® system can be further combined, for example, with optimized wear joints and seals and special wear coatings for rotors. Retrofitting older pumps is also possible without any problems. We offer you a conversion kit for this purpose. With our calculator, we can show you the potential total cost of ownership savings in advance.

Konsultasi Individu

Dapatkan penawaran yang dipersonalisasi!

hubungi sekarang

Advantages

Umur pemakaian yang panjang
Tergantung pada aplikasinya, perpanjangan masa pakai hingga lebih dari tiga kali lipat
Perawatan yang mudah
Karena tampilan potensi residu, perencanaan pemeliharaan yang mudah
Tidak ada ruang tambahan
Meningkatkan pompa Anda tanpa kebutuhan ruang tambahan

Technique

Rotary screw pump components showing a cutaway view, highlighting the helical rotors and casing design for efficient fluid movement.
  • No adaptation of piping and pump base plate required for retrofitting
  • Controlled, defined adjustment of the xLC® adjustment system
  • High reliability due to robust design and simple operation
  • Permanently high efficiency of the NEMO® pump through readjustment of the stator
  • Rapid amortisation of the purchase due to reduced need for spare parts and longer maintenance intervals

Relive Webinar xLC-Pilih

Dapatkan rekaman gratis Anda sekarang dan
menghemat uang di masa depan

minta sekarang

Suku cadang, dokumen, data

Temukan MyNETZSCH, portal pelanggan digital Anda.

Daftar gratis sekarang

Kontak dan perusahaan Anda di NETZSCH

Ada pertanyaan khusus? Hubungi kami untuk bantuan atau isi formulir kontak.

AI Overview
An error occurred. Please try again.