
PERIPRO® Hose Pump Industrial Version
Robust and powerful design for conveying abrasive and aggressive media
Highly durable and maximum serviceability at the same time: The robust design of the PERIPRO® hose pump in the industrial version from NETZSCH enables you to convey abrasive and aggressive media in a wide variety of applications in a maintenance-friendly way.
Due to its heavy-duty design, the hose pump is ideally suited for pumping materials with up to 70 percent solids and fibre content. As a result, the robust PERIPRO® industrial design covers numerous different industrial applications. With our hose pumps, you can convey even abrasive and aggressive media such as sludge, ceramic slurry or cement with maximum process reliability. In addition, the hose pump offers you an extremely high suction capacity with a high level of maintenance friendliness at the same time. The large diameter of the rollers, the low lubricant requirement and the few wearing parts make this possible.
Maximum accuracy with minimal wear
Hose pumps do not need any wear-intensive valves or mechanical seals. The only wearing part is the easily replaceable hose. This reduces your downtimes and service times and saves you money at the same time. In addition to reversible delivery, the PERIPRO® hose pump offers you the highest dosing accuracy with less than one percent deviation. Even in applications with variable pressure, the pump can dose with the highest accuracy. This means that nothing stands in the way of precise and powerful conveying.
Advantages
Technique

- Long service life of the hose thanks to large rollers
- Insensitive to dry running
- Easy conveying of large solids and fibres
- Easy to service
- Very low lubricant consumption
- Extremely high suction capacity
- Gentle and reversible conveying possible
- High dosing accuracy
- Corrosion resistant

Worldwide service and support for your pump and system
Our service and support do not end with the purchase. From consultation, spare parts and maintenance to the repair and modernisation of your pump - we support you right from the start.
Thanks to our worldwide service network, we are ready for you around the clock in case of an emergency.
Applications PERIPRO® hose pump industrial version
FAQ peristaltic pumps
Peristaltic pumps are particularly suitable for pumping aggressive, abrasive, highly viscous or shear-sensitive media. Typical areas of application include the chemical and process industries, water and wastewater technology, mining and industrial applications with high operational safety requirements.
PERIPRO® peristaltic pumps from NETZSCH Pumps & Systems impress with their robust design, simple sub-assembly and reliable delivery of even the most difficult media. Peristaltic pumps offer you extremely high suction power with minimal maintenance. In addition, they do not require wear-intensive valves or mechanical seals. The only wear part is the hose, which is easy to replace.
Peristaltic pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes and media with a high solids content. Even aggressive or corrosive media can be conveyed safely.
Yes, peristaltic pumps are self-priming and have very good suction behaviour. They can start up reliably even with a dry suction line and are therefore suitable for applications with changing fill levels.
Peristaltic pumps require little maintenance. The main wear part is the hose, which is replaced regularly depending on the application and operating conditions. Replacing the hose is quick and easy.
All relevant original spare parts for peristaltic pumps are available from NETZSCH Pumps & Systems. These include, in particular, hoses, rollers and bearings. All spare parts are precisely matched to the respective pump design and ensure reliable and safe operation.
The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, technical drawings and the operating and maintenance instructions also assist. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.
PERIPRO® peristaltic pumps are available with different hose materials, which are adapted to the respective pumped medium. Selection is made on an application-specific basis to ensure chemical resistance and optimal service life.
The service life of the hose depends on factors such as the medium, pressure, speed and operating time. A long service life can be achieved through correct design and adapted operating parameters.
Yes, peristaltic pumps are very well suited for dosing applications. The almost linear delivery characteristic enables precise and reproducible dosing, even under changing process conditions.
Peristaltic pumps operate efficiently, especially when pumping demanding media. An optimised design helps to reduce energy consumption and operating costs.
The experts at NETZSCH Pumps & Systems will assist you in selecting, designing and integrating the right peristaltic pump. Based on your process data, a technically and economically optimal solution will be developed.











