APPLICATIONS & SOLUTIONS
NETZSCH Pump Solutions for the Food & Pharmaceutical Sectors
We find and develop the perfect positive displacement pump for your individual application
As the world's leading supplier in the field of positive displacement pumps, NETZSCH offers you an individual and innovative solution in the areas of food and pharmaceuticals. With our pumps and systems, you can convey your products gently and cleanly in compliance with all hygiene guidelines.
Due to the wide variety of applications in the food and pharmaceutical sectors, we develop customised and sophisticated pump solutions for your request on a global level. We promise you Proven Excellence – outstanding performance in all areas. Whether in the beverage industry, in the production of foodstuffs, for pumping cosmetics or pharmaceutical products, in dairy operations or for conveying oils and fats, the satisfaction of our customers is always our top priority.
Whether in the beverage industry, in the production of foodstuffs, for pumping cosmetics or pharmaceutical products, in dairy operations or for conveying oils and fats, the satisfaction of our customers is always our top priority.
Special challenge: High hygienic standards
In the food industry, a pump is far more than just a piece of technology. Only pumps handling food with care and precision can preserve its value and taste. In addition to hygienic TORNADO® rotary lobe pumps, NOTOS® multi screw pumps and NEMO® progressing cavity pumps, our product portfolio also includes PERIPRO® peristaltic pumps. Together, these pumps offer safe and particularly gentle pumping of food, cosmetic and pharmaceutical media. You can rely on us for innovative pump solutions meeting highest standards of cleanability, product safety and process efficiency.

To be approved for use in the food and pharmaceutical industries, pumps from NETZSCH are subject to a whole range of hygienic guidelines, from the EHEDG to the 3-A Sanitary Standard to specifications from the US Food and Drug Administration (FDA). Our pumps and systems open up new possibilities for you and your manufacturing processes.
Practical experience from food and pharmaceuticals
Discover first-hand advantages of our solutions in action and the crucial role our service plays in ensuring smooth operation. Customers from the food and pharmaceutical sectors report on their experiences with NETZSCH.
Hygienic pumping of liquids and emptying of barrels
In the food and beverage industry, gentle pumping and compliance with hygiene standards play a crucial role. With the oil-free TORNADO® T.Sano® rotary lobe pump, you can dose even sparkling and semi-sparkling wines extremely precisely and gently at the same time. Since pumping is based on the positive displacement pump principle, pressure fluctuations or shear forces are ruled out. This prevents unwanted foam formation. Thanks to our unique barrel emptying systems, barrels' almost residue-free and hygienic emptying are also no problem. If space is limited, a closed system with a TORNADO® T.Sano® rotary lobe pump is also suitable for emptying. Thanks to the innovative design, you can convey products in a soup kitchen, for example, under the highest hygiene standards.
Efficient and temperature-controlled conveying of critical media
The pumping of edible oils and fats entails a wide variety of requirements. In addition to the high hygienic conditions, the TORNADO® T.Sano® rotary lobe pump offers you meagre maintenance costs. In addition, the rotary lobe pump ensures gentle and efficient pumping. This makes it suitable even for the production of products such as mayonnaise. Thanks to the innovative design and the unique belt drive, the rotary lobe pump gives you the maximum flexibility in every application situation. If required, the T.Sano® can be mounted on a mobile stand.
Hygienic, flexible and gentle transport of edible oils and fats
The pumping of edible oils and fats entails a wide variety of requirements. In addition to the high hygienic conditions, the TORNADO® T.Sano® rotary lobe pump offers you meagre maintenance costs. In addition, the rotary lobe pump ensures gentle and efficient pumping. This makes it suitable even for the production of products such as mayonnaise. Thanks to the innovative design and the unique belt drive, the rotary lobe pump gives you the maximum flexibility in every application situation. If required, the T.Sano® can be mounted on a mobile stand.
Hygienic and reliable conveying in dairies
Particularly demanding media such as yoghurt, milk, condensed milk or other dairy products require extremely gentle conveying in compliance with the strictest hygiene standards. With the NEMO® progressing cavity pump, you can transport even the most demanding products without wear and lubrication. This enables you to convey aseptic products and it protects your product from contamination. Thanks to the dead space-free design, the progressing cavity pump can be cleaned without being removed from the system. This saves you considerable time and costs during servicing.
Increased efficiency and hygiene when pumping pharmaceutical products
The pumping of pharmaceutical media such as cell mass and suspension, for example in insulin production, requires the highest efficiency and hygiene. Due to the special design of the NEMO® progressing cavity pump without dead space and the optimal cleanability, the pump fulfils even the strictest hygiene guidelines. In addition, the progressing cavity pump offers you long maintenance intervals. The residue-free cleanability in the system and the long service intervals increase your productivity.
Success stories
Food & Pharmaceuticals
- Almond Chocolate
- Almond Nougat Paste
- Apples
- Bakery Products
- Beer
- Brewer's Grains
- Chili & Tomato
- Shampoo Transfer Pumps
- Chocolate
- Cocoa Mass
- Condensed Milk
- Critical Media
- Diatomaceous Earth Suspension
- Edible Oil and Fat
- Fish Waste
- Fruit Juice Concentrates
- Fruit and Vegetables
- Insulin
- Maggots
- Mayonnaise
- Pork Offal
- Sauces
- Sparkling Wine
- Turkey Meat
- Wine
- Yoghurt
Products for the food and pharmaceutical sectors
FAQ food & pharmaceuticals
For a reliable configuration, information on the pumped medium, temperature and viscosity, the desired flow rate and delivery head, and the operating mode is required, among other things. In addition, the application and further relevant information, such as hygiene standards, certifications or cleaning processes, play an important role.
The selection of the appropriate pump type is based on your process data and technical requirements. For complex applications, design and application engineering are also involved to develop a technically and economically optimal solution. For a quick enquiry, please use the corresponding enquiry form.
You can easily request a quote using the contact form, by email or by telephone. Our experts will be happy to assist you in selecting the right pump solution.
The service life of the rotor and stator can be significantly increased by taking several measures. These include proper pump design, selection of suitable materials, speed adjustment, use of dry-running protection, and regular maintenance. Using original spare parts also contributes to a longer service life and even higher economical operation.
NETZSCH Pumps & Systems offers a wide range of pump technologies. These include progressing cavity pumps, rotary lobe pumps, multi screw pumps and peristaltic pumps. The optimal pump type is selected depending on the application and medium.
For applications in the food and pharmaceutical industries, pumps from NETZSCH Pumps & Systems can be designed to meet relevant hygiene and regulatory requirements. Depending on the pump, these include designs and concepts in accordance with EHEDG, FDA and 3-A. Food-compliant materials, defined surface qualities, and CIP and SIP capabilities are considered based on the application. The selection of appropriate materials is always made in close coordination with process and industry-specific requirements to ensure maximum product and process safety.
Pump solutions from NETZSCH Pumps & Systems are suitable for a wide range of sensitive and demanding media in the food and pharmaceutical industries. These include liquid, viscous or pasty products as well as shear-sensitive media. Typical examples are food raw materials, concentrates, syrups, creams, emulsions, suspensions
Tests with various pumping technologies can be conducted in our Fluid Innovation and Application Centre (FIZ) upon request.





