Service Seminar

Đào tạo thực hành

Một kỹ thuật viên đang kiểm tra một máy bơm khoang tiến trong xưởng trong khuôn khổ buổi thực hành về bảo trì máy bơm.
25.06.2024 08:30 – 26.06.2024 15:00
25.06.2024 08:30 – 26.06.2024 15:00 (Berlin UTC +02:00)
Waldkraiburg, Đức

Practical Training to Increase the Efficiency of Your Pump Maintenance

We train you on our products! The technical training at NETZSCH Pumps & Systems focuses on practical experience. We will show you how to avoid or eliminate errors during commissioning, maintenance and repair, thereby increasing your efficiency in the long term. Benefit from more than seven decades of experience in manufacturing positive displacement pumps.

During the two-day technical training course on the NETZSCH Campus in Waldkraiburg, you will gain in-depth product knowledge of NEMO® progressing cavity pumps and TORNADO® rotary lobe pumps from the global specialist in handling complex media experts. In addition, we offer you an optional third day on which the NOTOS® multi screw pumps and PERIPRO® peristaltic pumps technologies are discussed in detail. To maximise your benefit, the number of participants is limited to ten. Registrations will be considered on a first-come, first-served basis.

Schedule of the practical training 

Day 1 – 8:30 am to 5 pm:

  • Welcome, company presentation and factory tour
  • Operating principle and series of NEMO® progressing cavity pumps
  • Assembly and disassembly of NEMO® progressing cavity pumps
  • Explanation and overview of the different joint types
  • Assembly and disassembly of the joints
  • Damage patterns of progressing cavity pumps

Day 2 – 8:30 am to 3 pm:

  • Operating principle and series TORNADO® rotary lobe pumps
  • Assembly and disassembly of TORNADO® rotary lobe pumps
  • Damage patterns of rotary lobe pumps
  • Explanation and overview of various mechanical seals and belt drives
  • Assembly and disassembly of mechanical seals
  • Special designs and variants of TORNADO® rotary lobe pumps
  • Methodical troubleshooting

Day 3 – 8:30 am to 3 pm (optional):

  • Operating principle and series of PERIPRO® peristaltic pumps
  • Assembly and disassembly of PERIPRO® peristaltic pumps
  • Operating principle and series of NOTOS® multi screw pumps
  • Assembly and disassembly of NOTOS® multi screw pumps
  • Methodical troubleshooting

Training fee

The participation fee for the two-day practical training course is 770 euros per person plus VAT. For the optional third day, only 130 euros are added.

From the second registration of a company, the fee is reduced to 670 euros (two days) or 800 euros (three days) per person.

The training fee includes the substructure, a training certificate, lunch and refreshments during breaks on each training day, and a joint dinner on the first training day. Participants are responsible for their own travelling expenses and hotel costs.

Accommodation during the practical training

For the period of the practical training, we have blocked a certain number of rooms for you in a hotel about five minutes away by car. The participant reserves the hotel room.
If you want a hotel room, don't hesitate to contact us when booking the training course.

Withdrawal from participation in practical training

A written cancellation up to 14 days before the start of the course is free of charge. Please understand that we will charge a processing fee of 100 euros plus VAT. We must set the total participation fee for registrations that are not cancelled in writing up to three days before the start of the course. Changing your registration to another staff member at any time is possible.

AI Overview
An error occurred. Please try again.