
APPLICATIONS & SOLUTIONS
NETZSCH Pumping Solutions for Battery Production
We find and develop the optimum pump for your individual application
Innovation and decades of experience working with positive displacement pumps that's precisely what NETZSCH combines in the field of battery manufacturing. As a global specialist in complex fluid management, we offer you innovative solutions worldwide for all process steps in battery manufacturing.
The satisfaction of our customers is our top priority. Whether in mining, in the extraction of raw materials for battery production, in mixing, wet grinding and in the de-clumping process as well as in coating – NETZSCH has the perfect solution for your problem.
Pumps optimised for battery production application
Our specifically designed pumps for the battery sector enable you to gently convey all the required liquids, including electrode slurries, without pulsation and dose them with extremely high precision whilst fulfilling the most stringent safety and environmental regulations. Together with you, we will find the optimised solution for you and your application in the battery sector.

Our pumps and systems guarantee you pulsation-free delivery, high-precision dosing and maximum corrosion resistance in all process steps. We promise you Proven Excellence – outstanding performance in all areas.
Powerful pumps for raw material extraction for battery production
Batteries consist of anodes, cathodes, separators and electrolytes. Lithium, nickel and manganese are also usually used in coupling inserts for the battery components. Pumps are needed to transport the extracted raw materials. This is where NETZSCH enters the game. The pumps and systems from the global specialist in complex fluid management are extremely powerful and reliable. Since they can be operated over a long period without problems, they represent a cost-effective solution. With NEMO® progressing cavity pumps, you can pump even viscous media such as lithium slurry at low operating speeds. This significantly reduces wear and tear. In addition to the technology of progressing cavity pumps, which has been tried and tested for decades, our TORNADO® T.Envi® rotary lobe pumps and PERIPRO peristaltic pumps in industrial design are also suitable for pumping viscous slurries and liquids with high solids content. Depending on the medium and individual requirements, we select the right pump for you from our broad product portfolio.
Robust pumps from NETZSCH for the mixing and wet grinding process
Pumps are also essential in the mixing and wet grinding process step. This process treats and recycles the sludge from electrolytes that accumulate during battery manufacturing. In the wet grinding of electrolyte sludge, NEMO® progressing cavity pumps in FSIP® design and PERIPRO peristaltic pumps in industrial design convey the sludge through the grinding process particularly efficiently thanks to their innovative design. The pumps ensure the abrasive sludge is fed into a container where it gets ground. This grinding process breaks the sludge into smaller particles, which can be more easily separated from the metals they contain. The high abrasiveness demands everything from the pumps in the process. The robust construction of the NETZSCH pumps nevertheless offers you a long service life compared to other technologies. In addition, the progressing cavity and peristaltic pumps are particularly compact and easy to service. The FSIP® design of the progressing cavity pumps saves you up to 66 percent in maintenance time, and PERIPRO peristaltic pumps have only one wearing part anyway - the hose. This reduces your downtimes and service times while at the same time saving you money.
Constant delivery in the wet grinding and deagglomeration process
In battery manufacturing, pumps have a significant task in wet grinding and deagglomeration. During the production of batteries, especially lithium-ion batteries, electrolyte sludge is produced, consisting of metals and other particles that accumulate. This sludge must be treated and recycled to recover the metals and reduce the environmental impact. We offer different pump technologies to convey the sludge through the wet grinding process. Depending on the medium and the individual application, the PERIPRO peristaltic pump in industrial design and the TORNADO® T.Envi® rotary lobe pump is suitable in addition to the NEMO® BY progressing cavity pump in industrial design. Furthermore, using these pumps prevents the clumping of the sludge.
NETZSCH pumps: Conveying and precise dosing in the mixing process
Pumps also play a key role during the mixing process of electrolytes in battery manufacturing. The electrolytes, such as lithium salts in a liquid or polymer form, must be accurately metered and homogeneously mixed to ensure consistent and effective battery performance when manufacturing lithium-ion batteries. In this process step, pumps are essential to transport and dose the electrolytes from the containers to the mixing tanks. Depending on the type of slurry, rotary lobe pumps, peristaltic pumps and progressing cavity pumps offer you high flow rates and the highest dosing accuracy. In addition, due to the choice of materials and construction, NETZSCH pumps have high corrosion resistance and, thus, long service lives. This sustainably reduces your costs for maintenance and servicing.
Highest dosing accuracy in the coating process in battery production
The final step in battery manufacturing is the coating process. The pumping system is an integral part of the battery production lines that convey many types of glue, battery fluid, and other media. Various primary raw materials are pumped into the agitator tank, which is agitated at high speed. Optimally suited for the coating process are the NEMO® progressing cavity pumps from NETZSCH. They enable you to continuously feed even highly viscous and highly concentrated slurries and pulsation-free to the coating system. This allows you to achieve a thin and uniform coating thickness. Since the pump system conveys and doses the medium with low pulsation and maximum precision, it meets even the highest coating process requirements in battery production.
NETZSCH pumps for recycling batteries
The demand for lithium-ion batteries, especially electric vehicles, is growing. While, according to a Statista study, battery capacities of only 215 gigawatt hours (GWh) were needed in 2020, this will already be 680 GWh in 2025. Along with the increasing demand for batteries, the demand for recycling and reprocessing old batteries is also rising. NETZSCH offers you various displacement pumps to help you recycle old batteries. Our experts will support you in finding the perfect pump solution for recycling old batteries.
Success stories
NETZSCH product portfolio in the battery sector
Câu hỏi thường gặp về sản xuất pin
Bơm thể tích dương được sử dụng trong các ứng dụng yêu cầu vận chuyển chính xác và ổn định các chất lỏng có độ nhớt cao, chứa hạt rắn hoặc nhạy cảm với lực cắt. Các ứng dụng điển hình bao gồm chuyển chất lỏng giữa các bồn trộn và bồn đệm, tuần hoàn trong quá trình trộn, vận chuyển đến hệ thống phủ (ví dụ: quy trình slot-die hoặc doctor-blade), xả thùng chứa và thùng phuy, cũng như định lượng các chất phụ gia hoặc chất kết dính.
Bơm khoang tiến triển hoạt động dựa trên nguyên lý thể tích dương, cung cấp lưu lượng thể tích liên tục và gần như không có dao động. Điều này đặc biệt quan trọng để đảm bảo độ dày lớp phủ đồng đều trong quá trình phủ, vận chuyển nhẹ nhàng các cấu trúc hạt nhạy cảm, quá trình ổn định ngay cả khi độ nhớt thay đổi và độ chính xác cao trong việc định lượng. Đặc biệt đối với các hỗn hợp chứa vật liệu hoạt tính như graphite, LFP hoặc NMC, ứng suất cắt thấp giúp ngăn chặn sự thay đổi hình thái của hạt.
Ngoài ra, các hỗn hợp anot và catot, dung dịch chất kết dính như PVDF hoặc CMC/SBR, dung dịch phụ gia và các hệ thống dựa trên dung môi hoặc nước có thể được vận chuyển. Sự phù hợp cụ thể phụ thuộc vào loại bơm và thiết kế đặc thù cho ứng dụng. Các chuyên gia của chúng tôi sẽ đồng hành cùng bạn ngay từ đầu để hỗ trợ thiết kế bơm.
Tốc độ dòng chảy tỷ lệ thuận với tốc độ của bơm. Kết hợp với công nghệ truyền động phù hợp, điều này cho phép độ chính xác cao, dễ dàng hiệu chuẩn, thay đổi công thức nhanh chóng và khả năng điều khiển xuất sắc cho các dây chuyền sản xuất tự động.
Trong quá trình phủ, độ đồng đều của dòng chảy quyết định chất lượng của lớp điện cực. Bơm khoang tiến triển tạo ra dòng chảy thể tích liên tục, gần như không có dao động và dạng lớp. Kết quả là độ dày lớp phủ ổn định, có thể tái tạo, giảm hiện tượng vệt và cửa sổ quá trình ổn định hơn trong điều kiện vận hành thay đổi.
Việc chuyển đổi sản phẩm, vệ sinh và xác nhận đóng vai trò quan trọng trong sản xuất pin. Tùy thuộc vào thiết kế, các khái niệm CIP và SIP, thiết kế giảm không gian chết, tháo lắp nhanh chóng và khả năng xả hết dư lượng tốt đều có sẵn. Điều này giúp giảm thời gian ngừng hoạt động và tăng khả năng hoạt động của nhà máy trong dài hạn.
Đúng. Tải trọng cắt thấp ngăn chặn sự phá vỡ của các cụm hạt, nhiệt độ không mong muốn và sự thay đổi trong tính chất lưu biến. Điều này rất quan trọng để đảm bảo cửa sổ phủ ổn định và chất lượng sản phẩm nhất quán.
Sự biến động trong quá trình sản xuất được giảm thiểu thông qua việc giao hàng liên tục, độ chính xác cao trong việc định lượng và thiết kế chắc chắn. Điều này cho phép đạt được chất lượng ổn định trong các chu kỳ sản xuất dài.
Đúng vậy, bơm thể tích dương có thể được tích hợp dễ dàng vào các dây chuyền tự động. Điều khiển tốc độ thông qua biến tần tần số hoặc bộ điều khiển servo, tích hợp vào hệ thống PLC hoặc hệ thống điều khiển, và kết nối với các cảm biến đo lưu lượng, áp suất hoặc khối lượng là những ứng dụng phổ biến.
Khi nói đến các dung môi như N-methyl-2-pyrrolidone (NMP), trọng tâm là an toàn lao động, phòng ngừa phát thải và tính toàn vẹn của hệ thống. Các bơm kết nối từ tính, như bơm kết nối từ tính MY củaNEMO® , được phát triển đặc biệt cho sản xuất pin, được sử dụng cho các ứng dụng này. Nhờ truyền động mô-men xoắn không tiếp xúc, các bơm này được đóng kín hoàn toàn và không yêu cầu phớt trục động. Điều này ngăn chặn sự thoát hơi dung môi, tăng cường an toàn lao động, tuân thủ các quy định môi trường và giảm chi phí bảo trì.
Trong quá trình tái chế, bơm thể tích dương được sử dụng ở bất kỳ nơi nào cần vận chuyển đáng tin cậy các chất lỏng chứa rắn, có độ nhớt cao hoặc không tuân theo định luật Newton. Các ứng dụng điển hình bao gồm vận chuyển và tuần hoàn bùn tro đen, cấp liệu cho các phản ứng trong quá trình chiết xuất, xả bồn, thùng chứa hoặc máy ép lọc, và định lượng các hóa chất quá trình như axit, bazơ, chất khử hoặc chất keo tụ.




