APPLICATIONS & SOLUTIONS

NETZSCH Pump Solutions for Chemical, Pulp & Paper Industries

We find and develop the perfect positive displacement pump for your individual application 

As a worldwide leading supplier of positive displacement pumps, NETZSCH offers you individually optimised pump solutions in the areas of chemicals, pulp and paper. With our pumps and systems, you can safely convey even the most challenging media.

We globally develop customised and sophisticated solutions for you in the chemical, pulp and paper sectors. Fluids that are hazardous to health and the environment, highly viscous products, products containing solids or sensitive products require pumps that can handle even the most challenging media in hermetically isolated systems. 

We make no compromises when it comes to your safety. In any case, the satisfaction of our customers is always our top priority. Together with you, we will find the product optimally tailored to you and your requirements.

Tư vấn ngay

Nhận ưu đãi!

liên hệ ngay

Pumps for chemical, pulp and paper applications 

Sự đa dạng của các loại phương tiện truyền thông trên thị trường, dù là truyền thống hay phức tạp kết hợp với các yêu cầu cụ thể của từng quy trình sản xuất, là gần như vô tận. Hãy tận dụng kinh nghiệm dày dặn của chúng tôi và danh mục sản phẩm bơm thể tích dương dành cho ngành hóa chất và giấy. An toàn và độ tin cậy của sản phẩm là ưu tiên hàng đầu của chúng tôi, được đảm bảo thông qua việc áp dụng công nghệ bơm phù hợp. Chúng tôi hỗ trợ khách hàng bằng tư vấn chuyên nghiệp và các giải pháp độc quyền đã được cấp bằng sáng chế.

Christian Müller
Christian Müller
Giám đốc lĩnh vực kinh doanh Hóa chất, Bột giấy và Giấy khu vực EMENA

We promise you Proven Excellence – outstanding performance in all areas. NETZSCH rotary lobe pumps, progressing cavity pumps, and multi screw pumps, combined with our grinders, constantly guarantee you the right solution for your process. Together with you, we will find the product optimally tailored to you and your requirements.

Các ngành công nghiệp hóa chất, bột giấy và giấy

Discover first-hand advantages of our solutions in action and the crucial role our service plays in ensuring smooth operation. Customers from the chemical, pulp and paper industries report on their experiences with NETZSCH.

““Sự xuất sắc đã được chứng minh của NETZSCH không chỉ là một khẩu hiệu đối với Grønbech. Đó là điều chúng tôi trải nghiệm hàng ngày thông qua chất lượng sản phẩm, kiến thức chuyên sâu về ứng dụng và sự chuyên nghiệp của đội ngũ nhân viên. Hợp tác chặt chẽ với NETZSCH, chúng tôi không ngừng củng cố kiến thức về các loại bơm thể tích và hệ thống tùy chỉnh của họ, đảm bảo cho khách hàng thuộc nhiều ngành công nghiệp khác nhau rằng ngay cả những thách thức phức tạp nhất trong việc xử lý chất lỏng cũng được giải quyết với độ tin cậy vận hành cao, lưu lượng tối ưu và hiệu quả năng lượng vượt trội.”

Tom Lerdangaard
Tom Lerdangaard
GRØNBECH

“Zander & Ingeström đã hợp tác với NETZSCH được hơn 50 năm nay. Mặc dù NETZSCH là một nhà sản xuất lớn trên toàn cầu, chúng tôi vẫn cảm thấy mình là một phần của đại gia đình. NETZSCH là một đối tác sáng tạo, luôn đi đầu trong việc phát triển các sản phẩm mới cho các ứng dụng đòi hỏi khắt khe. Khách hàng Thụy Điển của chúng tôi đánh giá cao chất lượng tuyệt vời và độ tin cậy của dòng sản phẩm đa dạng mà NETZSCH cung cấp.”

Marcus Wigren
Marcus Wigren
Zander & Ingeström

“In terms of value, NETZSCH products are durable and reliable, offering long-term cost savings. The pumps, like the NEMO® progressing cavity pump, deliver great all-round performance under varying conditions, essential for our operations. Overall, NETZSCH’s combination of superior customer service, expert knowledge, and high-performing products makes them a trusted partner for our business. Operating in the harshness of the mining industry these pumps continue to impress.”

Ben Howgate
Ben Howgate
WA Grouting Systems PTY LTD

“Chúng tôi đánh giá cao sự hợp tác với NETZSCH. Sự chuyên nghiệp, chất lượng, độ tin cậy và sự hiểu biết chung của chúng tôi đã góp phần quan trọng vào sự phát triển của các dự án. Cùng nhau, chúng tôi phát triển các giải pháp sáng tạo và bền vững không chỉ đáp ứng các tiêu chuẩn kỹ thuật cao nhất, mà còn mang lại giá trị gia tăng thực sự và độ tin cậy trong quy trình cho khách hàng của chúng tôi.”

Oscar Spiess
Oscar Spiess
HänyTec AG

„Dù là ứng dụng trong lĩnh vực môi trường, hóa chất, thực phẩm, dược phẩm, hay trong ngành dầu khí (thượng nguồn hoặc hạ nguồn), NETZSCH luôn cung cấp các loại bơm chất lượng cao đúng thời hạn. Chúng tôi đã xem NETZSCH là đối tác đáng tin cậy cho các giải pháp bơm phức tạp trong hơn 20 năm qua. Chúng tôi tin tưởng rằng không chỉ đáp ứng mà còn vượt qua kỳ vọng của khách hàng nhờ vào chuyên môn của NETZSCH, từ việc lựa chọn bơm phù hợp đến việc triển khai thành công dự án.”

Arnas Svaldenis
Arnas Svaldenis
Trường Đại học UAB Hidora

Continuous conveying of abrasive and corrosive paints and varnishes

With NEMO® progressing cavity pumps, you can continuously convey even abrasive and corrosive media in the paint and paper industry. In addition, the progressing cavity pump enables you to achieve exact dosing despite a lack of fluidity. Thanks to the innovative design of the NEMO®, maintenance and service can be carried out even when the pump is installed. This saves you time and the associated maintenance costs. The TORNADO® T.Proc® rotary lobe pump has a particularly long service life when pumping abrasive media in the construction industry. You can even pump dispersion-containing primers with a high solids content without any problems. In this way, you extend the service life by more than three times.

Exact mixing and dosing of different components in silicone production

Precise dosing plays a decisive role with modern materials. With the NEMO®barrel emptying systems, you can dose a wide variety of material components without interruption. This is made possible by the unique design of the progressing cavity pump. NEMO® barrel emptying systems guarantee you precision requirements of plus or minus one percent. Thanks to the high delivery volume and the uninterrupted dosing, you can significantly reduce your processing time.

3000

various products have already been transported in the chemical, pulp and paper sectors

Fast and reliable conveying in paper and pulp processing

With TORNADO® rotary lobe pumps, you can convey media with special requirements such as kaolin slurry or ceramic slurry quickly and reliably. Thanks to an individual material pairing optimally matched to the product, the TORNADO® enables you to achieve particularly long running times with low maintenance. To save time when cleaning and maintenance work is required, you can remove the front of the pump chamber in a few easy steps. This makes the entire pumping area easily accessible. Thus you can shorten your service times, which is a great advantage, especially with abrasive and highly viscous products.

Safe, gentle and efficient conveying of highly reactive substances

Substances such as lithium sludge are among the most demanding pumped media. The NEMO® progressing cavity pumps in stainless steel design enable you to pump highly reactive substances efficiently. Thanks to the innovative design, you pump the medium continuously and gently, i.e. free of pressure fluctuations, pulsation or shear forces. This keeps maintenance and servicing costs extremely low, even with demanding media.

Uninterrupted and safe discharge of numerous hazardous substances  

The pumping of fatty acids in the chemical industry is subject to stringent legal requirements. With the innovative TORNADO® T.Proc® rotary lobe pumps, you can pump the most diverse types of hazardous substances in compliance with all regulations. The unique design enables you to safely empty and fill tanks or tank trucks and ensures a particularly long service life. Even solvent-contaminated media pose no problems for the TORNADO®. This means that you expose neither personnel, consumers, nor the environment to unnecessary danger.

Câu hỏi thường gặp về hóa chất, bột giấy và giấy

NETZSCH Pumps & Systems cung cấp một loạt công nghệ bơm đa dạng, bao gồm bơm khoang tiến, bơm cánh quay, bơm ốc vít đa cấp và bơm peristaltic. Loại bơm tối ưu được lựa chọn tùy thuộc vào ứng dụng và môi trường làm việc.

Tùy thuộc vào loại bơm và thiết kế, có thể bơm được nhiều loại chất lỏng khác nhau. Phạm vi ứng dụng bao gồm từ nước đến các hóa chất ăn mòn hoặc có tính ăn mòn cao, cho đến các chất lỏng có độ nhớt cao, dạng bột nhão hoặc chứa chất rắn. Trong ngành công nghiệp hóa chất và giấy, các chất như nhựa đường, hóa chất, phân bón, axit béo và chất phủ dính, cùng nhiều chất khác, được vận chuyển một cách đáng tin cậy. Ngay cả các chất lỏng đòi hỏi cao như hydrogel, bùn gốm, bùn kaolin, mực in offset và các hỗn hợp cũng không gây khó khăn cho các giải pháp bơm của chúng tôi.

Để có một cấu hình đáng tin cậy, cần cung cấp thông tin về chất lỏng được bơm, nhiệt độ, độ nhớt, lưu lượng mong muốn, áp suất đầu ra và chế độ hoạt động, cùng với các yếu tố khác. Ngoài ra, tình trạng lắp đặt và các tiêu chuẩn hoặc quy định phải tuân thủ, chẳng hạn như API, ATEX hoặc tiêu chuẩn vệ sinh, cũng đóng vai trò quan trọng.

Việc lựa chọn loại bơm phù hợp dựa trên dữ liệu quy trình và yêu cầu kỹ thuật của quý khách. Đối với các ứng dụng phức tạp, thiết kế và kỹ thuật ứng dụng cũng được áp dụng để phát triển giải pháp tối ưu về mặt kỹ thuật và kinh tế. Để yêu cầu tư vấn nhanh chóng, vui lòng sử dụng biểu mẫu yêu cầu tương ứng.

Bạn có thể dễ dàng yêu cầu báo giá thông qua biểu mẫu liên hệ, email hoặc điện thoại. Các chuyên gia của chúng tôi sẽ rất hân hạnh được hỗ trợ bạn trong việc lựa chọn giải pháp bơm phù hợp.

Một bộ bơm hoàn chỉnh thường bao gồm bơm, động cơ truyền động, bộ nối và đế bơm. Tùy thuộc vào ứng dụng, các thiết bị điều khiển bổ sung, cũng như công nghệ đo lường và an toàn, có thể được tích hợp.

Đúng, có thể mua bơm mà không kèm theo bộ truyền động. Tùy thuộc vào thiết kế của bơm, các sản phẩm này được giao hàng đã lắp ráp sẵn. Các yêu cầu đặc biệt hoặc sự khác biệt có thể được sắp xếp theo từng trường hợp cụ thể.

Để nâng cao an toàn vận hành và độ tin cậy của quá trình, các phụ kiện như biến tần tần số, hệ thống bảo vệ chống chạy khô, thiết bị giám sát phớt cơ khí và thiết bị giám sát áp suất thường được sử dụng. Việc lựa chọn được thực hiện dựa trên yêu cầu cụ thể của ứng dụng.

Các đề xuất về máy móc thường có hiệu lực trong vòng 90 ngày. Các thỏa thuận khác có thể được áp dụng tùy theo từng dự án cụ thể.

Thời gian giao hàng cho các đơn vị tiêu chuẩn thường khoảng sáu đến tám tuần kể từ nhà máy sau khi nhận đơn đặt hàng. Các thiết kế đặc thù cho dự án hoặc theo yêu cầu của khách hàng có thể khác với thời gian này.

Vui lòng liên hệ với đại diện hoặc đại lýđịa phương của quý khách tại quốc gia của quý khách để được hỗ trợ các yêu cầu quốc tế.

AI Overview
An error occurred. Please try again.