APPLICATIONS & SOLUTIONS

NETZSCH Pump Solutions for Oil & Gas Upstream

We find and develop the perfect positive displacement pump for your individual application 

Special challenges require innovative and customised solutions. As the world's leading supplier of positive displacement pumps, NETZSCH offers you pumps and systems individually adapted to your requirements in the oil and gas upstream sector on a global level.

Together with you, we find and develop the optimal pump solution for your application. The satisfaction of our customers is always our top priority at NETZSCH. Whether you are a large oilfield operator or a small production company, we dedicate ourselves to your projects with the highest passion. 

We promise you Proven Excellence – outstanding performance in all areas. To meet the increasing technological requirements, we are continuously researching innovative solutions together with universities and operators of our pumps.

Tư vấn ngay

Nhận ưu đãi!

liên hệ ngay

Efficient opportunities for oil & gas upstream

Trong công nghệ sản xuất của ngành dầu khí, máy bơm không chỉ đơn thuần là một thiết bị. Nó quyết định liệu các nguồn tài nguyên có thể được khai thác và sử dụng một cách đáng tin cậy và hiệu quả về mặt kinh tế hay không, ngay cả trong những điều kiện khắc nghiệt nhất. Các giải pháp của chúng tôi dành cho các ứng dụng thượng nguồn được thiết kế đặc biệt để đáp ứng những yêu cầu này. Chúng mang lại hiệu suất đáng tin cậy ngay cả trong điều kiện khó khăn, giúp khai thác và tận dụng tối đa tiềm năng sản xuất hiện có.

Hermann Braun
Hermann Braun
Giám đốc lĩnh vực kinh doanh Dầu khí thượng nguồn khu vực EMENA

Our innovative pumps for the oil industry are characterised by a robust and reliable design. Together with you, we define the requirements in the planning phase and thus globally find the pumps and systems optimally matched to your application.

Practical experiences from oil and gas upstream

Discover first-hand advantages of our solutions in action and the crucial role our service plays in ensuring smooth operation. Customers from the oil and gas upstream sector report on their experiences with NETZSCH.

“Since OPHKL’s initial engagement with NETZSCH, we have consistently found them to be world-class in many aspects. Their comprehensive offering of products and services has provided us with a competitive edge. Every team member from NETZSCH involved in this project has demonstrated fairness, courtesy, and, above all, the highest level of professionalism in all interactions.”

Brian Slovensky
Brian Slovensky
OP Hawler Kurdistan Ltd.

“NETZSCH has a very good attitude of cooperation in the process of commissioning and dealing with problems, reflecting a high degree of contractual spirit and dedication, and won the unanimous praise of all parties to the project, hereby, we would like to thank you for your high quality service. Looking ahead, we hope that we will continue to adhere to the concept of win-win cooperation, work hand in hand, collaborate, and create new brilliance.”

China Petroleum Engineering & Construction Corporation
China Petroleum Engineering & Construction Corporation
CPECC

“Thanks to the great service provided by NETZSCH, the costs for installing the pumps in the borehole were significantly reduced. Not only were the system costs reduced, but the service life was also increased.”

Onur Akın
Onur Akın
Durko Çevre Enerji Tekniği ve Tic. A.Ş.

“NETZSCH offers a broad range of progressive cavity pumps that, together with our expertise in designing, optimizing and troubleshooting PCP wells, have consistently met and exceeded our client’s expectations. The products are reliable, durable, and engineered to handle demanding applications in our industry. In addition to the quality of the products, the support provided has been outstanding.“

Vasile Mogos
Vasile Mogos
Endurance Lift Solutions International

“We would like to express our appreciation for the services and products provided by NETZSCH. We confirm that the work was carried out professionally, in accordance with the agreed specifications, and to our full satisfaction. The support and responsiveness of the team throughout the process were highly commendable, and the delivered system has met our performance expectations. We look forward to continuing our collaboration and will not hesitate to recommend NETZSCH for similar projects in the future.“

Mohamed Bedir
Mohamed Bedir
SEAHARVEST

"Hợp tác với NETZSCH đã diễn ra rất hiệu quả và suôn sẻ kể từ khi Vermilion tiếp quản trách nhiệm vận hành. Đáng chú ý nhất là việc quản lý thiết bị một cách hiệu quả, cho phép sử dụng nhanh chóng khi cần thiết, cùng với sự sẵn sàng của các chuyên gia hỗ trợ cho các câu hỏi về thiết kế."

Curd Djalvand
Curd Djalvand
Vermilion Energy Đức

„Dù là ứng dụng trong lĩnh vực môi trường, hóa chất, thực phẩm, dược phẩm, hay trong ngành dầu khí (thượng nguồn hoặc hạ nguồn), NETZSCH luôn cung cấp các loại bơm chất lượng cao đúng thời hạn. Chúng tôi đã xem NETZSCH là đối tác đáng tin cậy cho các giải pháp bơm phức tạp trong hơn 20 năm qua. Chúng tôi tin tưởng rằng không chỉ đáp ứng mà còn vượt qua kỳ vọng của khách hàng nhờ vào chuyên môn của NETZSCH, từ việc lựa chọn bơm phù hợp đến việc triển khai thành công dự án.”

Arnas Svaldenis
Arnas Svaldenis
Trường Đại học UAB Hidora

Efficient conveying of diluted oil fields with high gas content

Do you want to increase the efficiency when pumping an oil-water mixture? The specially designed, underground-driven progressing cavity pumps make it possible. At the same time, you reduce your costs as well as the consumption of resources. Even changing pumping conditions, including a high free gas content, pose no problems for the underground-driven progressing cavity pump. As a result, you can pump efficiently from even heavily diluted oil fields.

High-tech solutions for efficient production in oil and gas fields

Oil production 4.0 - Digitalisation is also changing the pump industry more and more. Thanks to the complete downhole sensor system, you can pump particularly efficiently even under challenging conditions with our high-tech pump solutions. In addition to pressure, temperature and vibration sensors, the sensor technology provides data on the pressure at the pump, from which you can conclude the dynamic level of the fluid in the borehole. This allows you to detect possible faults at an early stage and prevent damage to the pump. In addition, thanks to the digitalisation of oil and gas fields, you optimise your efficiency in crude oil production.

60000

downhole pumps have already been supplied by NETZSCH

Crude oil production under the most difficult external conditions

The location of the oil fields is as varied as their quality. Even strongly changing temperatures, such as in deserts, do not pose a problem for the downhole progressing cavity pumps. Despite the challenges, the innovative progressing cavity pumps with drive heads impress with long service life and long maintenance intervals. This keeps your life cycle costs low, which ensures profitability even with lower quality crude oil.

Permanent monitoring of the dynamic fluid level

The conditions underground are constantly changing. With our underground driven progressing cavity pumps, you monitor the dynamic fluid level and frequently adjust the operating conditions thanks to the unique frequency control. This increases efficiency, and you achieve a significant reduction in energy consumption. At the same time, thanks to the special design, environmental pollution caused by leaks above ground is ruled out.

Environmentally and climate-friendly crude oil production

Environmental and climate protection play a central role at NETZSCH. In contrast to the use of conventional horse-head pumps, both the pumping elements and the motor are located in the borehole in the case of NETZSCH's underground-driven progressing cavity pumps. This means that you rule out environmental pollution due to leakage above ground.

Conveying the most challenging media in oil and gas fields

Oil-sand mixtures pose problems for many pumps in crude oil production. With the unique progressing cavity oil pumps, you can efficiently convey even the most challenging media without damaging the product. By avoiding pulsation and shear forces, you prevent possible emulsion effects. This makes it much easier for you to separate the mixtures at the surface. At the same time, they increase your efficiency by up to 60 percent, thanks to the innovative design.

Câu hỏi thường gặp về lĩnh vực thượng nguồn dầu khí

Các hệ thống NETZSCH PCP được sử dụng để khai thác dầu thô từ loại nhẹ đến loại siêu nặng, cũng như các chất lỏng có hàm lượng cát, nước hoặc khí cao. Chúng đặc biệt phù hợp cho các ứng dụng thượng nguồn đòi hỏi khắt khe, liên quan đến độ nhớt cao và điều kiện khai thác thay đổi. Nhờ thiết kế chuyên biệt cho từng ứng dụng, các hệ thống này có thể được điều chỉnh chính xác để phù hợp với điều kiện chất lỏng và giếng khoan cụ thể.

Các hệ thống PCP mang lại hiệu suất cao với mức tiêu thụ năng lượng tương đối thấp, cũng như chi phí đầu tư và vận hành thấp. Hoạt động liên tục, gần như không có dao động và có độ cắt thấp của các hệ thống này cho phép xử lý chất lỏng một cách đặc biệt nhẹ nhàng. Điều này cũng có thể tạo điều kiện thuận lợi cho quá trình tách hỗn hợp dầu-nước sau đó và góp phần vào hiệu quả chung của toàn bộ quy trình.

Đúng vậy. Các hệ thống PCP của NETZSCH được thiết kế để xử lý dầu thô có hàm lượng cát, nước và khí cao. Hình dạng bơm, vật liệu cao su và các bộ phận bổ sung dưới đáy giếng được lựa chọn dựa trên điều kiện thực tế của chất lỏng và giếng khoan. Điều này cho phép hệ thống PCP được cấu hình cụ thể để đáp ứng các yêu cầu khai thác tương ứng.

Tùy thuộc vào dòng máy bơm, thiết kế và điều kiện vận hành, các hệ thống PCP của NETZSCH có thể đạt áp suất xả lên đến 300 bar và lưu lượng lên đến 550 m³/ngày. Tùy theo ứng dụng, hệ thống cũng có thể xử lý các chất lỏng có hàm lượng cát lên đến 40 phần trăm. Các giới hạn về nhiệt độ, vật liệu cao su và hiệu suất được đánh giá riêng biệt cho từng ứng dụng dựa trên dữ liệu về chất lỏng và giếng khoan.

Đúng vậy. Ngoài rô-to và stato, NETZSCH Pumps & Systems còn cung cấp các bộ phận được thiết kế đồng bộ để tạo thành các giải pháp hệ thống PCP hoàn chỉnh. Các bộ phận này bao gồm đầu truyền động, bộ tách khí, bộ cố định mô-men xoắn, các giải pháp BOP tích hợp và các bộ phận khác trong giếng khoan. Cấu hình hệ thống và phạm vi cung cấp cụ thể được xác định riêng cho từng dự án dựa trên các yêu cầu của ứng dụng thượng nguồn tương ứng.

AI Overview
An error occurred. Please try again.