NEMO® Bơm kết nối từ tính MY
Đóng kín hoàn toàn: Không rò rỉ chất lỏng hoặc khí nguy hiểm
Safe and cost-effective pumping of hazardous media: The NEMO® MY magnetically coupled pump, specially developed for handling slurries with high viscosity, makes it possible.
The magnetically coupled pump from NETZSCH is hermetically sealed. This prevents aggressive, toxic or abrasive liquids and gases from escaping. The leakage-free pump guarantees maximum safety for your employees and the system. While the failure of a mechanical seal system leads to a seal leak, this is prevented with the NEMO® MY thanks to the magnetic coupling. The magnetic coupling is also less cost-intensive than a pump with a mechanical seal or other sealing system. This allows you to reduce your costs and make production even more efficient.
Bơm kết nối từ tính: Hệ thống làm kín không cần bảo trì
Một ưu điểm khác của Bơm trục vít magnatically coupled NEMO® MY là hệ thống làm kín không yêu cầu bảo trì. Nhờ sử dụng kết nối từ tính, không cần đảm bảo áp suất làm kín luôn ổn định và mức chất lỏng trong hệ thống làm kín được duy trì. Ngoài ra, bơm kết nối từ tính, được phát triển đặc biệt cho việc bơm bùn, cho phép bơm các chất lỏng có độ nhớt lên đến 20.000 cps. Bơm này cũng tuân thủ tiêu chuẩn ATEX và có thể sử dụng an toàn trong môi trường có nguy cơ nổ.
Advantages
Technique

- Available for applications requiring ATEX
- Lower capital costs compared to a double mechanical seal
- No seal leakage in the event of a support system failure
- No external services, compressed air or sealing fluid required
| Name | Pressure max. (bar) | Capacity min. (m³/h) | Capacity max. (m³/h) | Speed (rpm) |
|---|---|---|---|---|
| NM005MY | 36 | 0.004 | 0.007 | 500 |
| NM008MY | 18 | 0.01 | 0.026 | 500 |
| NM011MY | 12 | 0.03 | 0.07 | 500 |
| NM015MY | 12 | 0.1 | 0.2 | 400 |
| NM021MY | 12 | 0.15 | 0.4 | 300 |
| NM031MY | 12 | 0.4 | 1.2 | 300 |
| NM038MY | 12 | 1.0 | 3.8 | 300 |
| NM045MY | 12 | 2,0 | 7,0 | 300 |
| NM053MY | 12 | 4,0 | 10,0 | 300 |
Further sizes and technical data on request.

Worldwide service and support for your pump and system
Our service and support do not end with the purchase. From consultation, spare parts and maintenance to the repair and modernisation of your pump - we support you right from the start.
Thanks to our worldwide service network, we are ready for you around the clock in case of an emergency.
Ứng dụng Bơm trục vít magnatically coupled NEMO® MY
Câu hỏi thường gặp về máy bơm trục vít
NEMO® máy bơm khoang tiến triển của NETZSCH Pumps & Systems nổi bật với khả năng bơm nhẹ nhàng, ít dao động, độ chính xác cao trong việc định lượng và phạm vi ứng dụng rộng rãi. Chúng đảm bảo lưu lượng ổn định ngay cả khi áp suất và thành phần chất lỏng thay đổi.
Tất cả các phụ tùng thay thế chính hãng phù hợp đều có sẵn cho các dòng bơm khoang xoắn của NETZSCH Pumps & Systems, bao gồm rôto, stato, phớt, các bộ phận nối và các bộ phận khác dễ bị mài mòn. Các phụ tùng này được thiết kế phù hợp chính xác với cấu trúc của bơm và đảm bảo độ tin cậy cao trong quá trình vận hành.
Các chuyên gia tại NETZSCH Pumps & Systems sẽ hỗ trợ quý khách trong việc thiết kế, lựa chọn và tích hợp máy bơm khoang tiến phù hợp – được thiết kế riêng cho các nhiệm vụ bơm và yêu cầu quy trình cụ thể của quý khách.