spa water

Bơm nước spa hiệu quả từ nguồn nước muối Glauber

Progressing cavity pump conveys healing water with a high brine content

High brine content, sodium sulphate, and chloride levels attack the systems, and the demands on pumps for conveying healing water are high. As a global specialist in complex fluid management, NETZSCH Pumps & Systems has sophisticated solutions for pumping spa water.

We will show you how to pump healing water with a high brine content efficiently and gentle simultaneously by using a progressing cavity pump with a drive unit at the surface.

Tư vấn ngay

Nhận ưu đãi!

liên hệ ngay
Nước spa chảy ra từ những vòi nước bằng đồng thau chạm trổ tinh xảo, tôn lên tác dụng trị liệu của nước muối có nồng độ cao trong các bồn tắm nhiệt.

Bơm nước spa có hàm lượng muối cao từ độ sâu

There are various reasons for wanting to pump water from great depths to the surface. On the one hand, this water can be used for geothermal purposes under optimal conditions. On the other hand, media are suitable as healing water for thermal baths due to their composition. The latter includes water with a high brine content. However, this poses significant challenges for pumps due to the ingredients. The original goal of the Saxony State Spa was to explore and develop brine exclusively for geothermal purposes. After a suitable location was found in the Elster Valley using exploration, i.e. a geophysical survey of fault zones, an exploratory borehole was drilled at a depth of 1,200 m, and a first pumping test was carried out.

Công nghệ đặc biệt cho nước khoáng có hàm lượng khoáng chất cao

During the exploratory drilling, those responsible came across highly mineralised water with exceptionally high sodium sulphate and chloride content. Due to the mineral content of the healing water, a special pump was needed to transport the medium gently to the surface. The aim was to cover the water demand of three pools in the thermal brine bath with a capacity of 450 cubic metres of healing water. In addition to the composition of the healing water, the challenge was to find a pump that would efficiently bring the fluid, which is unique in Germany, to the surface from a depth of 1,200 metres in the Elster Valley.

22

percent of salt content are no problem

Please accept Marketing Cookies to see that Video.

With the NEMO® BY progressing cavity pump in FSIP® design with xLC® stator adjustment system you can reduce maintenance time.   

Bơm khoang tiến triển vận chuyển hiệu quả

NETZSCH developed an innovative solution for pumping the spa water based on a downhole system initially designed for pumping in oil fields. Thanks to years of experience in the oil and gas sector, the solution was obvious to the global specialist in complex fluid management. Due to the borehole's small diameter of 95 millimetres, a progressing cavity pump with a drive unit at the surface was chosen. The advantage of this solution for pumping the healing water also lies in its rapid availability and maximum flexibility in the delivery rate and the medium to be pumped. No other pump system can cover such a wide range of delivery rates. For this reason, this pump technology is being used more and more frequently, especially during test phases.

Using a heating jacket for the pump, you can also heat the brine and dissolve more salt. To prevent the salt from crystallising and abrading the elastomer during pumping, the spring water was pumped with a brine content of 22 percent, i.e. diluted, and at a temperature of 42 °C. The brine was then pumped at a temperature of 50 °C. The speed of the progressing cavity pump was 100 to 200 revolutions per minute. This used the natural lubricating effect that brine exerted at higher flow rates and avoided elastomer abrasion. Since the unit has only a small number of wearing parts, life cycle costs are kept low. This significantly reduces your maintenance and servicing costs. However, it is not only the operators of the state spa who benefit from using the progressing cavity pump to pump the healing water to the surface. Visitors to the 4,500-square-metre spa landscape also enjoy various pools in which the brine is used in diluted form, allowing them to float weightlessly in the water. For example, there is a salt lake with a brine concentration of 15 percent and two pools with a brine content of ten and six per cent, respectively.

NEMO® BT immersible pumps with bracket or flanges

  • Medium: Spring water with a salt content of 22 %
  • Temperature: 42 °C
  • Rotations speed: 100 - 200 rpm
Bơm xoắn ốc NETZSCH® ( NEMO) được thiết kế để bơm hiệu quả nước khoáng có hàm lượng muối cao từ độ sâu lớn.