Sludge Removal Pump

sludge Removal Pump 

Thickened Sludge Removal Pumps for Wastewater Treatment Plants

NETZSCH Pumps and Systems is a manufacturer of robust reliable sludge removal pumps suitable for handling highly viscous sludge. NEMO® progressive cavity pump design, which is well-suited for pumping viscous and abrasive sludge in wastewater treatment plants.

NEMO® Progressing cavity pumps are ideal for the transfer of thickened sludge, sludge thickener, and dewatered sludge in wastewater, sewage, and effluent treatment plants. Our thickened sludge transfer pumps mostly reduced maintenance and servicing costs thanks to NEMO® progressing cavity pump in FSIP® design. 

You are a wastewater treatment plant operator and want to sludge transfer pumps to remove abrasive thickened sludge reliably. Then you've come to the right place. As a global expert in complex fluid management, NETZSCH Pumps & Systems, a leader in the field of complex fluid management, provides you with thickened sludge removal pump solutions that are individually tailored to your requirements.

We will show you the advantages of the NEMO® progressing cavity pump in FSIP® design ("Full Service in Place") with an xLC® stator adjustment system when thickened sludge pumping abrasive sludge from wastewater treatment plants.

Individual Consulting

Get a personalized offer!

contact now
Wastewater treatment plant with flowing thickened sludge and foam, highlighting the efficient pumping process and infrastructure.

Reliable thickened sludge removal pumps used for wastewater treatment plants

Wastewater treatment plant operators worldwide face the daily challenge of pumping sludge thickener from A to B in continuous operation. In addition to the high solids content, the composition of the thickened sludge in wastewater treatment plants demands a great deal from the pumps and systems.

 Due to the wear-intensive applications, significantly higher service and maintenance costs are expected. Despite rising energy costs, keeping operating costs as low as possible is essential. Therefore, high reliability, service life, and easy service are decisive requirements for pumps in wastewater treatment plants. 

How challenging isit for thickened sludge removal pumps in wastewater treatment facilities to pump abrasive thickened sludge? 

In a wastewater treatment plant in Bavaria, the operator used a progressing cavity pump that transferred thickened sludge with a solids content of eight percent to an intermediate tank for disintegration. Due to the abrasive content of the sludge thickener, the progressing cavity pump was subject to high wear.

 This led to high maintenance and servicing costs. Iron and aluminum salts from the tertiary sludge and the industrial plant located in the village also contributed to this. This meant that the Rotorrotor,Rotors,rotorsrotor-stator pair had to be serviced regularly after about 8,000 hours of operation. 

For the new acquisition, the responsible persons placed particular emphasis on the fact that the unit had a significantly higher reliability and service life and was particularly easy to maintain.

24000

operating hours without service

Please accept Marketing Cookies to see that Video.

With the NEMO® BY progressing cavity pump in FSIP® design with xLC® stator adjustment system, you can reduce your maintenance time by up to 66 percent.

How progressing cavity pump reduces costs for thickened sludge pumping?

NETZSCH found the right sludge removal pump for reliably pumping abrasive thickener sludge in the wastewater treatment plant. The NEMO® progressing cavity pump in FSIP® design is particularly maintenance-friendly and robust. Thanks to its innovative design, you can perform maintenance and service without removing it from the plant. This saves you up to 66 percent time.

 The thickened sludge removal pump used in the wastewater treatment plant in Bavaria is also equipped with the xLC® stator adjustment system, which allows the iFD-Stator® 2.0 to be readjusted and its service life multiplied. Beyond the previous service life, the pump can operate for 16,000 hours before the stator needs to be replaced. 

The progressing cavity pump runs 24 hours a day and achieves over 8,000 operating hours yearly at a flow rate of 1-3 m³/h. The advantages of the NEMO® progressing cavity pump in FSIP® design with xLC® stator adjustment system have tripled the service life when pumping sludge thickener and significantly reduced maintenance and servicing costs.

NEMO® progressing cavity pump in FSIP® design

  • Medium: Sludge with a solids content of 8 %
  • Flow rate: 1 to 3 m³/h
  • Operating hours: 24 h a day reaching over 8,000 operating hours a year
NEMO® progressing cavity pump in FSIP® design for efficient thickened sludge pumping in wastewater treatment plants.