PRODUCTS & ACCESSORIES

NOTOS® Multi Screw Pumps

Since 1979 NETZSCH has been manufactures and suppliers multi-screw pumps to serve a wide range of serval industries & applications with their efficient and unique design.

Flexible, efficient, and reliable: NOTOS® multi-screw pumps manufacture and specially design for serval industrial sectors and applications. NOTOS® pumps are designed to handle low to highly lubricating liquids with low to high viscosity, as well as shear-sensitive or chemically aggressive media.

The pumps have been optimized using the High-Efficiency Unique Design (HEUD) concept to give you maximum performance. Your satisfaction is always our top priority. That is why we offer you a wide range of materials. Our range of metallic materials extends from grey cast iron and chrome-nickel steel to duplex, super duplex, or Hastelloy steel. We promise you Proven Excellence - outstanding performance in all areas.

Your partner for innovative screw pump solutions

We offer our customers the full range of multi screw pump technology. In combination with our globally unique sales and service network, this makes us the preferred global partner for multi screw pumps.

Rainer Merkel
Rainer Merkel
Global Productline Manager NOTOS®

The technology of the multi screw pumps

The multi screw pump is a rotating positive displacement pump in which the shape of the rotors resembles a screw.  It consists of two or more rotors that rotate anticlockwise and a casing around the rotors.

Please accept Marketing Cookies to see that Video.

The rotors are designed with a regular, thread-like profile and mesh with each other like cogwheels. The cavities created by these three construction elements form the conveying spaces. When the rotors rotate, they move out in one machine direction and convey the medium from the suction side to the pressure side. 

The helical design also reduces noise compared to straight-toothed gear pumps. This significantly reduces your noise level in production. In addition, this type of pump is particularly suitable for incompressible, even viscous media for generating high pressures.

Individual Consulting

Get a personalized offer!

contact now

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Practical experience with NOTOS® multi screw pumps

Discover first-hand how our NOTOS® multi screw pumps perform in practice and the crucial role our service plays in ensuring smooth operation. Customers report on their experiences.

“Before switching to the new NETZSCH pump, emptying our barrels was a slow and time-consuming process. Since making the change, we’ve seen a dramatic improvement in efficiency. The new pump (NOTOS® 2NSH multi screw pump) has significantly reduced the time required, allowing our team to focus on other critical tasks. It’s been a game changer for our operations, and we couldn’t be more satisfied with the results.“

Stephen Richard
Stephen Richard
SunRype

“We have been using the NETZSCH two screw pump for our oil transfer operations, and it has consistently exceeded our expectations. Its robust design and precision engineering ensure smooth, pulsation-free flow, even when handling highly viscous oils. The pump’s efficiency and low maintenance requirements have significantly reduced our operational downtime and costs. Additionally, its ability to handle varying flow rates and pressures with ease has made it a versatile solution for demanding applications. We highly recommend NETZSCH for anyone seeking reliable, high-performance pumping solutions for oil and other challenging fluids.”

Matt Armstrong
Matt Armstrong
Fuelex Energy

“In Portugal, we have worked exclusively with NETZSCH for over 20 years. The high quality of the equipment and the ability to reach a wide range of activity areas have been a real added value to the Portuguese customers over the years.”

José Raposo
José Raposo
NETIMPRO

“This partnership marks an important milestone for us, as NETZSCH is a brand known for its quality, innovation, and reliability in the field of pumps. We are pleased to offer Czech and Slovak customers direct access to original products and technical support from one of the world’s leading manufacturers.”

Josef Rouš
Josef Rouš
Pro Pump s.r.o.

“NETZSCH is Fuglesangs most important pump partner, and we appreciate the very good cooperation and communication we have. The wide NETZSCH product portfolio offers the best quality, to the benefit of our customers' processes in many industries.“

Erik Michalsen
Erik Michalsen
Fuglesangs AS

“NETZSCH consistently delivers outstanding product quality with exceptional reliability. Their wide product range, combined with the flexibility to provide customized solutions, makes them a trusted partner for complex industrial needs. What truly sets them apart is their cooperative and professional team, always ready to support and collaborate effectively. In addition, their responsible and responsive after-sales service ensures long-term customer satisfaction and confidence.”

Mishkatur Rahman
Mishkatur Rahman
MnM Augsburg UG

FAQ multi screw pumps

Multi screw pumps are particularly suitable for the continuous conveyance of low-viscosity to high-viscosity media in applications with high requirements for a uniform, low-pulsation conveyance process. They are used in a wide range of industrial applications, including the oil and gas industry in the mid- / downstream sectors, shipping and shipbuilding, and power generation. In addition, multi screw pumps are used in the chemical and petrochemical industries, in the food, beverage, cosmetics and pharmaceutical industries, and in tank farms and terminal operations. They also make a reliable contribution to safe and efficient plant operation in lubrication and control oil systems, for example, in hydroelectric power stations.

Yes, NOTOS® multi screw pumps can also be designed for hygienic applications. Depending on the medium and process requirements, hygienic designs with suitable materials, surface qualities and sealing concepts are available. These meet the requirements of hygienically sensitive industries, such as food and pharmaceutical, and enable safe, product-friendly pumping and easy cleaning.

NOTOS® multi screw pumps offer numerous advantages for demanding industrial applications. They are characterised by smooth, almost pulsation-free operation and run quietly and with minimal vibration. High efficiency combined with low NPSHr ensures energy-efficient and safe operation, even under difficult suction conditions. In addition, NOTOS® multi screw pumps enable excellent handling of highly viscous media and provide gentle, shear-free pumping. The robust design contributes to a long service life and low maintenance requirements. Depending on the version, the pumps are also suitable for hygienic applications and are available in hygienic designs, for example, as 2NSH, CIP and SIP compatible.

Multi screw pumps are suitable for pumping low to high viscosity media as well as lubricating and non-lubricating liquids. Depending on the design and type, both clean and shear-sensitivemedia, as well as corrosive or abrasive media, can be reliably pumped, as can liquids with low solid content. Even media containing gas can be pumped safely, depending on the application-specific design. Typical examples include crude oil, heavy oil, heating oil, lubricants, fuels, bitumen and other liquid or viscous media.

Depending on the type and application-specific design, multi screw pumps cover a very wide range of performance and applications. The flow ranges from a few m³/h to around 3,000 m³/h, while operating pressures in low-pressure applications can reach around 160 bar. In addition, multi screw pumps are suitable for a very wide viscosity range, extending up to several hundred thousand cSt. They also offer a high degree of flexibility in temperature: Depending on the choice of materials and seals, media temperatures rangingfrom around −20 °C to over 300 °C are possible.

Yes, multi screw pumps are specially designed for continuous operation and continuous pumping processes. They deliver consistent pumping performance under fluctuating operating conditions and are therefore ideal for supply and transfer applications.

Yes, NOTOS® multi screw pumps are used in numerous applications in the oil and gas industry, both in the midstream and downstream sectors. These include transfer processes, injection applications, supply systems, and auxiliary and ancillary units.

Yes, multi screw pumps have good self-priming properties and are suitable for applications with changing fill levels or difficult suction conditions.

Whether multi screw pumps can run dry depends on the type of pump and its design. NOTOS® 2NSH and NOTOS® 4NS pumps can run dry for short periods, depending on their design and if they’re only used for a limited time. On the other hand, NOTOS® 3NS and NOTOS® 2NS pumps are not suitable for dry running and must be lubricated by the pumped medium during operation. An application-specific design is crucial to prevent damage and ensure safe operation.

Various drive options are available for multi screw pumps, enabling flexible adaptation to different operating conditions and system designs. Depending on the application, the pumps can be operated with a directly coupled electric motor with a fixed speed or with an electric motor in combination with a frequency converter control. In addition, versions with a hydraulic motor or air motor are also available. For special requirements, direct drives via gearboxes and diesel motor drives are also available. The selection of the appropriate drive concept is always application-specific, taking into account the process requirements and operational conditions.

Various materials are available for the construction of multi screw pumps, enabling optimal adaptation to the medium, operating conditions and environmental requirements. Standard material options include cast iron and ductile iron, cast steel and all common stainless steel grades. Duplex and super duplex stainless steels are also used for particularly demanding applications, such as corrosive media or increased mechanical loads. The final material selection is always application-specific to ensure high operational reliability and long service life.

Yes, NOTOS® multi screw pumps from NETZSCH Pumps & Systems can be designed to be API-compliant. They are designed and manufactured in accordance with the relevant API standards for applications in the oil and gas industry. These include API 676 for rotary positive displacement pumps, API 682 for mechanical seals and sealing systems, and API 526 for external safety and pressure relief valves. Depending on the application and project-specific requirements, minor deviations are possible and are transparently agreed upon in advance.

Multi screw pumps are robustly constructed and low-maintenance. Regular inspections and the replacement of wear parts as needed contribute to a long service life and high plant availability.

All relevant original spare parts are available for multi screw pumps from NETZSCH Pumps & Systems. These include spindles, bearings, shaft seals, gaskets, housing parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure reliable, safe operation.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, technical drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the correct original spare part.

Yes, multi screw pumps can be customised to a high degree for the respective application. NETZSCH Pumps & Systems offers numerous configuration options to optimally match the pump to the medium, process conditions and installation situation. These include selecting suitable materials and coatings, as well as application-specific screw profiles. In addition, various connection types, for example, DIN or ANSI-compliant, as well as hygienic couplings, are available. Different seal configurations, such as single or double mechanical seals and API flat seal systems, can also be implemented. Additional options such as heating jackets, linings, monitoring sensors and pressure relief valves are also available. In terms of installation, multi screw pumps can be designed flexibly, for example, for horizontal installation with a foot, vertical mounting on a socket or as a semi-submersible version. These versatile customisation options ensure each multi screw pump is designed precisely to meet the specific requirements of the application.

The selection of the right multi screw pump is based on an application-specific design. Decisive criteria include the required volume flow and operating pressure, the viscosity and temperature of the pumped medium, and its lubricating properties. The possible solids content, the planned installation situation, for example, horizontal, vertical, or semi-submerged, as well as standards and norms to be complied with, such as API, hygienic designs, or ATEX, also play an essential role. The experts at NETZSCH Pumps & Systems will assist you in selecting, designing and integrating the right multi screw pump. Based on your process data, a technically and economically optimal solution will be developed.

An extensive range of accessories is available for multi screw pumps to ensure safe and reliable operation. These include coupling protection devices and baseplates, as well as couplings with or without distance pieces. Internal or external pressure relief valves are also available. Temperature and vibration sensors for monitoring pump operation, as well as API plan sealing systems for double mechanical seals, are also available. Heating and cooling jackets can also be used as replacement or supplementary components. All spare parts are precisely matched to the respective multi screw pump and contribute to high operational reliability and a long service life.

AI Overview
An error occurred. Please try again.