Chemical Process Pump

Chemicals

Chemical Transfer Pumps for Aggressive Chemicals Industry 

NETZSCH is one of leading chemical transfer pumps manufacturer and suppliers in India. Our Rotary lobe pumps have proven their performance and efficiency against centrifugal pumps. By using a chemical transfer pump, you can pump dangerous goods into explosive areas.

Do you use a centrifugal pump to empty tank wagons filled with aggressive chemicals such as tenside? In this case, problems such as interrupted delivery flows, production downtimes, and high personnel costs are undoubtedly familiar to you. If you are tired of dealing with these issues daily, you are in the right place at NETZSCH Pumps & Systems.

As a global specialist in complex fluid management, NETZSCH's portfolio includes innovative solutions for acids and chemicals transferring the aggressive chemicals industry. We show you how to benefit from replacing your centrifugal pump. We offer a variety of chemical transfer pumps and acid pumps. As a result, we reserve the right to change the pumps shown in this brochure without prior notice. We are continually working to improve the performance of our products/equipment.

Individual Consulting

Get a personalized offer!

contact now
A red tanker truck is parked at an industrial facility, preparing to unload aggressive chemicals safely in a controlled environment.

These are the challenges to be aware of when pumping industrial chemicals.

Emptying tank barrels filled with chemicals such as tenside poses numerous challenges for pumps. Difficulties include air inclusion that cannot be avoided when connecting to the pipeline. The gas bubbles initially cause a reduction in performance and an unsteady operation. If the gas entrapment is even higher, the flow finally breaks off entirely, resulting in an unplanned breakdown. 

Another challenge when pumping chemicals is the composition of the media. Many chemicals, including tenside, are thinned with solvents. Since most plastics are not resistant to solvents, the elastomer swells and thus impairs pump performance.

 In addition, chemicals, and acids often have to be pumped into potentially explosive areas. Therefore, the chemical pumps used must meet the required safety standards. An explosion-proof design is necessary to prevent a spark or other ignition source from forming. It is also important that the pumps do not run dry.

Chemicals Pumping : Benefit by replacing the centrifugal pump

A chemical company also struggled when chemicals pumping such as tenside. The company used a centrifugal pump to pump the tenside directly from a tank truck into the company's production area. The suction already caused considerable problems with the centrifugal pump. Air entering the pipe during the tank's connection formed air bubbles in the medium. This led to drops in performance and repeated flow interruptions. The centrifugal pump repeatedly broke down and had to be put back into operation by the staff. As a result, the drivers of the tank trucks often had to wait a long time until the tank was completely emptied.

 This resulted in high additional costs for dangerous goods transporters, as they generally have to adhere to strict driving and rest times. The chemical company contacted the global specialist in complex fluid management to solve these problems. 

Together with the company, the experts from NETZSCH found the optimal solution for the safe and reliable pumping of the chemicals. 

50000

cP viscosity are no problem

Please accept Marketing Cookies to see that Video.

The TORNADO® T.Sano® Rotary Lobe pump can pump the various chemicals safely in the chemical  industry.

How does the chemical transfer pump enable you to pump chemicals safely and reliably in explosive areas.

For the decision process, the unique requirements and operating conditions were taken into consideration. Therefore, the TORNADO® T.Proc® rotary lobe pump was chosen for the chemical process industry. Thanks to the all-metal design, even chemicals diluted with solvents can be pumped without reducing the pump performance. Compared to centrifugal pumps, the service life of all components in contact with the product is significantly increased. 

In addition, a universally applicable special elastomer was used for the seals, which have a high chemical and temperature resistance due to their composition.

 Since the chemical pump operates in an area declared as an explosive area, the pump must not run dry under any circumstances. For this reason, a pressure and a dry-running safety device have been integrated. Therefore, the chemical pump switches off automatically in case of a malfunction.

The chemical transfer pump has been running trouble-free in regular operation for several years and pumps 15 to 20 m³ of tenside per hour at four bar pressure. The chemical company no longer requires supervisory staff to empty the tank wagon due to this high reliability. The tank truck drivers can simply start the process and complete it within the planned time frame. 

Additional costs for waiting times, production downtimes, and the personnel required to restart the centrifugal pump no longer exist. What are you waiting for? Get a non-binding offer to replace your old centrifugal pump and make your production more efficient.

TORNADO® T.Proc® rotary lobe pump

  • Medium: Tenside chemical
  • Capacity: 15 to 20m³/h
  • Pressure: 4 bar
  • Viscosity: Up to 50.000 mPas
Rotary lobe pumps from NETZSCH designed for safely pumping aggressive chemicals like tenside in explosive areas. Efficient and reliable.
AI Overview
An error occurred. Please try again.