NEMO® BH Hygienic Pump in Compact Block Design, NETZSCH, Pumps, Systems
NEMO® Progressing Cavity Pumps

NEMO® BH Hygienic Progressing Cavity Pump

The ideal pump solution for conveying complex liquids in Hygienic and Sanitary Applications

The NEMO® BH Hygienic Progressing Cavity Pump is ideal for sanitary applications to convey highly viscous, shear sensitive, abrasive, and solids-containing media in food, beverage, pharmaceutical, cosmetic, and certain chemical/biochemical industries.

This pump provides continuous, low-pulsation, and low-shear, liquid conveyance, making it ideal for critical processes in the food, cosmetics, pharmaceutical, chemical, and biochemical industries.

This progressing cavity pump is best suited in applications where high sanitary standards is critical. Its critical design features include FDA Certified Materials, compliant mechanical seals, and liquid contact areas that are free of dead space.  The primary area of application is to handle shear-sensitive, and thin to viscous media, with or without solids. The NEMO® BH Pump guarantees hygienic conveying and high dosing accuracy, with less than one percent deviations, ensuring precise and reliable performance.

The hygienic design of the pump components is suited for CIP (Clean-in-Place) and SIP processes. It meets stringent regulatory standards for cleanliness and safety in the food processing industry.

NEMO® BH Hygienic Pump Meets Numerous Hygiene Guidelines

NEMO® pumps are designed, manufactured, and tested to comply with  the following standards: 

  • FDA Compliance: Meets the stringent requirements of the Food and Drug Administration (FDA).
  • EU VO 1935/2004 Compliance: It conforms to the European Union regulations for materials intended to come into contact with food.
  • 3-A Sanitary Standard: Complies with the 3-A Sanitary Standards of the USA, guaranteeing high hygiene levels.

Please accept Marketing Cookies to see that Video.

Individual Consulting

Get a personalized offer!

contact now

Advantages of NEMO® BH Hygienic Pump

Gentle Conveyance in Sanitary applications
The Pump ensures gentle handling of products, preserving their integrity/quality during conveyance
Hygienic Design
All product-contacting surfaces are polished to prevent build-up and facilitate easy cleaning.
 
 The pump seal in the flow path ensures constant flushing of media and doesn't settle in the seal area. 

 Materials used are FDA Compliant  
Compact Design and Flexible Installation
The closed-couple drive design makes the pump compact and easy to install in the systems.

The Pump design allows the capability to have reversible flow with the same hydraulic performance

NEMO® BH Hygienic Pump Construction

The NEMO® BH Hygienic Progressing Cavity Pump features a compact design with a directly flanged drive and open hygienic pin joints. It has no dead spaces or crevices that could cause fluid deposits, ensuring excellent cleanability. 

The pump seals comply with hygienic industry standards. The pumping elements - the Rotorrotor,Rotors,rotorsrotor is made with compliant materials and polished for a smooth finish for no fluid deposits, and the elastomer part in the stator is compliant with FDA Standards for sanitary applications.

The suction and discharge housings are of specific design to ensure smooth flow and avoid settling of the liquid medium in any dead spots or crevices. The surfaces are polished to meet the application demand. The end connections come with options to provide hygienic connections. The pump is an equipped construction with CIP-able design.

The shaft seal is in the flow path of the liquid and is wetted and lubricated with the process liquid. The pump is equipped with food industry-compliant mechanical seals for reliability and safety. The design of the pump is suited for reverse flow. The pumps are ideal for viscous, shear-sensitive liquids and those with solids, ensuring high hygiene standards.

A pump stator with reduced elastomer wall thickness allows for a wide operating temperature range. The stator inlet has a conical shape for improved feed into the pumping elements.

A thermal stator protector (STP-2 or STP-D) guards against overheating and dry running. FDA-certified connecting shaft seals are used for sanitary applications. All product-contact surfaces are smoothly polished to prevent medium deposits and facilitate cleaning.

The pump can also include a heating jacket over the stator and pump housing to maintain the media temperature sensitive to temperature changes.

A gray industrial pump with a motor and a helical rotor, designed for fluid transfer in various applications.
  • Flow rates from 1 LPH up to 140m3/hr, ensuring efficient handling of complex fluids in food industries.
  • Conveyance of fluids against high differential pressures of up to 24 Bar.
  • Capable of pumping high-viscous, abrasive liquids containing solid particles and shear-sensitive substances.
  • Suitable for viscous liquids up to 1 to 3 Million cP, showing its capability for various types of fluid consistencies it can handle.
  • Excellent in dosing viscous fluids such as flavors and additives used in the process.
  • Excellent suction capability and is hence suited for vacuum applications.
  • CIP Capability: Capable of Clean-in-Place (CIP), facilitating hygiene and thorough cleaning.
  • Suction Capability: Excellent priming under vacuum conditions, ensuring smooth conveyance without cavitation.
  • Flexible rod: Free of dead space, wear-free, and maintenance-free for residue-free transfer.
  • Installation Options: Can be installed horizontally or vertically for flexibility.
  • Optimum for Temperature-sensitive liquids. Optional heating/ cooling for the pump housing and stator to maintain the appropriate medium temperature.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM015 BH24up to0,7800
NM021 BH24up to2800
NM031 BH24up to5600
NM038 BH24up to12600
NM045 BH24up to20550
NM053 BH24up to30550
NM063 BH24up to40500
NM076 BH24up to55350
NM090 BH12up to80300
NM105 BH12up to120250

Further sizes and technical data on request.

Two engineers discuss a blueprint while observing a large machining tool in a workshop, emphasizing teamwork in manufacturing.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BH Hygienic Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.

FAQs

The NEMO® BH Hygienic Pump is specifically designed for sanitary applications in industries such as food, pharmaceutical, cosmetic, and chemical. Its optimal process characteristics make it ideal for operations requiring high standards of hygiene and cleanliness.

NEMO® BH Hygienic Pump key attributes include crevice-free pump design, polished surfaces for easy cleaning, optional jacketing for maintaining the temperatures of the media, and patented hygienic joints. 

It is compact, efficient, and suitable for hygienic applications in the food, pharmaceutical, cosmetic, and chemical industries. The pump is also CIP and SIP capable, ensuring optimal hygiene.

The pump delivers flow rates of up to 140 m³/h at pressures up to 24 bar. These capabilities make it suitable for a wide range of hygienic applications, especially those involving viscous media that require heating or cooling. It can also be used for dosing, transferring, and injecting process liquids.

The pump is designed, manufactured, and tested according to stringent hygiene standards, ensuring the highest level of safety and reliability. The pump components are compliant with FDA standards, the 3-A Sanitary Standard of the USA, and EHEDG Design standards.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Contact Us for Expert Hygienic Pump Solutions

While faced with needs or challenges in conveying complex fluids in sanitary applications we can offer the right design of NEMO® BH Hygienic Pump. Our team of experts is here to provide personalized advice and solutions tailored to your specific needs.

Contact us and experience the precision, reliability, and efficiency of the NEMO® BH - Hygienic Pump!

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.