NEMO® SA Aseptic Pump
NEMO® Progressing Cavity Pumps

NEMO® SA Aseptic Progressing Cavity Pump

The Ideal Pump Solution for Hygienic and Aseptic Applications

NEMO® SA Aseptic Pumps

The NEMO® SA Aseptic Pump is specifically designed for hygienic and aseptic applications in industries such as pharmaceuticals, food, cosmetics, and biotechnology. This pump is constructed to meet stringent hygienic and aseptic standards such as 3A and EHEDG to ensure sterile process requirements throughout the pumping process.  The aseptic pump design features a crevice-free, maintenance-free flexible rod, and aseptic seals, to ensure CIP (Cleaning in Place) and SIP (Sterilization in Place), allowing for thorough cleaning and sterilization without disassembly, making it ideal for aseptic processes. 

The NEMO® Pump is built with polished surfaces of the required Ra value, no dead spaces, and an open pin joint ensuring that it meets the high standards required in sensitive processes like pharmaceuticals. This design is compliant with the US 3-A Sanitary Standards and EHEDG design specifications.

The NEMO SA Pump design is perfectly suited for continuous, pressure-stable, gentle, and low-pulsation conveyance, as well as speed-proportional dosing, making it best suited in the food, pharmaceutical, cosmetic, and chemical/biochemical industries.

Individual Consulting

Get a personalized offer!

contact now

Advantages of the NEMO® SA Aseptic Pump

Highest sanitary & aseptic standards
Ensures optimal hygiene and sanitary needs by sealing all hermetic areas.
CIP/SIP enabled

Allows thorough and efficient cleaning and sterilization without the need for disassembly, minimizing downtime.
Minimizes product loss and ensures thorough cleaning
The tangential arrangement of the cleaning ports and eccentric pressure port design allow for smooth product flow in the suction and residue-free self-emptying and ensures thorough cleaning.

NEMO® SA Aseptic Pump Construction

The NEMO® SA Aseptic Pump is designed with advanced features to maintain product integrity and meet stringent hygiene and aseptic standards.

The pump design incorporates a joint-free flexible rod to transfer the torque and is polished and free from dead spaces and crevices. This overall pump design prevents any accumulation of media, making the pump best suited to clean and maintain sanity while allowing quick access during maintenance. Furthermore, the pump features a fully enclosed aseptic static shaft seal that complies with sanitary standards, ensuring that the media remains clean during the pumping process.

The pump housing is constructed with polished, smooth surfaces to the prescribed Ra values to prevent product adherence to the surface. It is designed with a reduced diameter and a product inlet positioned closer to the shaft, ensuring that the pump chamber is entirely free of dead space. This optimizes the flow of the product through the pump, improving the overall efficiency.

The cleaning and sterilization ports are arranged tangentially, while the pressure port is positioned eccentrically to allow for residue-free self-emptying. All sealing points are engineered for steam or sterile condensate, and the pipework is pre-installed to prevent environmental contamination.

The stator is of a reduced elastomer wall thickness, allowing it to operate effectively at wide operating rage in the conveying and cleaning phases. The status comes with a protector to safeguard against dry running and overheating. The pump's design, featuring a bearing housing and drive shaft, allows compatibility with a wide range of pressures.

NEMO® SA Aseptic Pump is its integration of Cleaning in Place (CIP) and Sterilization in Place (SIP) capabilities. This allows for thorough cleaning and sterilization without the need for disassembly, ensuring the pump can maintain aseptic conditions throughout the operation.

Stainless steel screw pump designed for efficient fluid transfer in industrial applications.

NEMO® SA aseptic pumps adhere to FDA regulations and EU-VO 1935/2004 standards, meet the United States 3-A Sanitary Standards, and are EHEDG Compliant. They are designed to manage a wide array of applications with the following specifications:

  • Flow ranges upto 120 m3/hr
  • Differential pressures upto 12 bar
  • Capable of handling a wide variety of media, including bacteriologically sensitive, toxic, contaminated, shear-sensitive, low to highly viscous, lubricating and non-lubricating, solids-containing or solids-free, thixotropic, dilatant, abrasive, and adhesive substances.
  • Aseptic pump Design: Crevice-free housing with a reduced diameter to prevent product sedimentation.
  • Temperature Capability: The pump is equipped with a stator with reduced elastomer wall thickness, ensuring that the pump is capable of handling both the conveying fluid and the cleaning fluids.
  • A thermal stator protector prevents dry running and overheating, ensuring optimal performance.
  • Compact and Space-Saving Design: Its compact construction allows the pump to fit into systems with space constraints, without compromising on efficiency and reliability. The drive is flanged directly to the pump's lantern, further reducing its footprint and simplifying maintenance.
  • Low Maintenance: The wear- and maintenance-free flexible rod design ensures long operational life, reducing the need for frequent maintenance and lowering operational costs.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM015 SA24up to0,7800
NM021 SA24up to2800
NM031 SA24up to5600
NM038 SA24up to12600
NM045 SA24up to20550
NM053 SA24up to30550
NM063 SA24up to40500
NM076 SA24up to55350
NM090 SA12up to80300
NM105 SA12up to120250

Further sizes and technical data on request.

Two engineers discussing a technical blueprint in a machinery workshop, emphasizing teamwork and precision in manufacturing.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® SA Aseptic Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine PD pump spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.

FAQs

These pumps are ideal for the food, pharmaceutical, cosmetic, and chemical/biochemical industries, particularly where hygienic and aseptic conditions are crucial.

The pumps adhere to FDA regulations, EU-VO 1935/2004 standards, 3-A Sanitary Standards, and EHEDG Compliant.

Yes, these pumps are designed to handle a wide variety of media, including abrasive and sticky media.

Polished surfaces that come into contact with the product prevent build-up, facilitating easy and effective cleaning through CIP/SIP processes. The shaft seals are designed for clean applications with no dead spaces.

The aseptic pump can be installed both horizontally and vertically, providing flexibility for various applications.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Contact us to get Expert Pump Advice

Discover the efficiency and reliability of our NEMO® SA Aseptic Pump .Contact our technical team to discuss your fluid handling needs and learn how our customizable pump solutions can optimize your operations. We offer consultation, technical support, and help in selecting the right pump for your application.

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and Rotorrotor,Rotors,rotorsrotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.

AI Overview
An error occurred. Please try again.