NEMO® BF Hopper Shaped Pump With aBP-Module®, NETZSCH, Pumps, Systems
NEMO® Progressing Cavity Pumps

NEMO® BF Hopper Design  Pump With aBP-Module®

The pump solution for highly viscous and crumbly substances that tend to bridge

The NEMO® BF hopper-design progressing cavity pump with aBP-Module® is specifically engineered to handle highly viscous and crumbly substances that tend to bridge. The aBP-Module® (Asynchronous Bridge Preventing) can be additionally mounted on the pump to prevent media bridging in the hopper and ensure continuous feeding into the conveying elements. 

This pump can be deployed across various industries to transfer high viscous and crumbly media efficiently across various industries.

The pump housing features an enlarged, rectangular feed hopper and a conical force-feed chamber for optimal product feed into the conveying elements like NEMO® BF Hopper Pump. Additionally, it incorporates a special coupling rod with a patented, positioned conveying screw. The pump is further enhanced by the aBP-Module® consisting of a top shaft with two internal spoke wheels—to prevent bridging and ensure efficient operation.

NEMO® BF hopper shaped pump prevents bridging

These create “moving shaft walls” which exert a shearing effect on the medium. This reliably prevents bridge formation in the pump shaft.  This also ensures the smooth conveying of solid-loaden, shear-sensitive, abrasive, adhesive, thixotropic or dilatant as well as lubricating and non-lubricating materials that have a tendency to bridge. The NEMO® is particularly compact and economical in block construction with flanged drive.

Please accept Marketing Cookies to see that Video.

Individual Consulting

Get a personalized offer!

contact now

Advantages of NEMO® BF Hopper Design  Pump With aBP-Module®

Uninterrupted Feeding of Viscous Medium
The aBP-Module® effectively prevents bridge formation, ensuring smooth and reliable operation even with highly viscous and crumbly substances. 
Service
Designed for easy maintenance, ensures minimal downtime and associated costs. The pump’s components are easily accessible, making routine checks and repairs simple and efficient.
Engineered Design
Pumps are adaptable and engineered to suit specific installation and process demands. Ensures compatibility with existing systems.

NEMO® BF Hopper Design Pump With aBP-Module® Construction

NEMO® BF Hopper Progressing Cavity Pump with aBP® module is offered with a suction housing, enlarged rectangular hopper design along the conveying screw, and conical force-feed chamber. 

The aBP® Module is mounted on the suction housing. This module creates "moving shaft walls" which exert a shearing effect on the medium. This reliably prevents bridge formation in the pump suction.  This also ensures the smooth conveying of solid-loaden, shear-sensitive, abrasive, adhesive, thixotropic or dilatant as well as lubricating and non-lubricating materials that have a tendency to be sticky and bridge. 

The NEMO® BF hopper pump with aBP Module is particularly compact and economical in block construction with a flanged drive. The drive is connected with a patented horizontally positioned coupling rod with a feeding screw for optimal feed into the conveying elements. 

The pump housing can be designed with materials in steel, stainless steel, or any other exotic materials and can also be coated for wear protection and chemical resistance. The stator is vulcanized into the housing with sealing on both sides in a variety of elastomers. The stator inlet is designed with a hopper-shaped opening for improved feed of the product into the conveying chamber.

Shaft seals are standard seals with single-acting, bi-directional, and wear-resistant. Upon request, with single- or double-acting mechanical seals of varied designs and from various manufacturers, cartridge and special seals as well as packed glands are available based on the complexity of the application. 

The NEMO® BF pump with aBP® Module construction is designed to convey high viscous and crumbly media reliability, and for ease of maintenance, making it a preferred choice for a wide range of industrial applications.

Industrial screw pump featuring a motorized unit and a helical rotor, ideal for fluid transfer applications.
  • Flow rates up to 60 m³/h at pressures up to 36 bar.
  • Conveyance to medium viscosities up to 3 Million cP.
  • Fluid temperatures up to 140 deg C.
  • Smooth, continuous, and gentle conveying of a wide range of media
  • Block Construction Robust and compact space saving block design.
  • Application-Specific Joints: Various joint options are available to ensure optimal performance for complex applications when handling viscous and solids containing liquids.
  • Seal Options: Standard mechanical seals are provided, with optional seals available for specialized needs.
  • Ideal Adaptation: The differential speed of the spoked wheels in the aBP-Module® can be precisely adjusted to suit the specific characteristics of the fluid being conveyed.
  • Easy & Quick Maintenance: Designed for easy serviceability, reducing downtime and maintenance costs.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM045 BF360.24up to 120
NM053 BF360.29up to 120
NM063 BF360.214up to 120
NM076 BF360.224up to 120
NM090 BF360.238up to 120
NM105 BF360.260up to 120

Further sizes and technical data on request.

Two engineers analyze technical documents near a CNC machine in a workshop, discussing project details.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BF Hopper aBP® Module Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.

FAQs

The NEMO® BF Hopper Shaped Pump with aBP-Module® is designed to handle a wide range of materials, including abrasive, highly viscous, and crumbly substances. The pump's innovative design and aBP-Module® ensure efficient, gentle, and continuous conveying of these challenging media.

The aBP-Module® (asynchronous Bridge Preventing module) consists of a top shaft with two internal spoke wheels that create "moving shaft walls," exerting a shearing effect on the medium. This prevents bridge formation in the pump shaft, ensuring smooth and reliable operation even with highly viscous and crumbly substances.

The NEMO® BF Hopper Shaped Pump's block construction design is robust and compact, making it ideal for installations where space is limited. This design also contributes to cost-effective performance with minimal maintenance requirements, ensuring that the pump is economical and efficient in operation.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Contact Us for Expert Solutions

Ready to optimize your industrial processes with the efficient and reliable NEMO® BF Hopper Shaped Pump with aBP-Module®? Our team of experts provide personalized advice and solutions tailored to your specific needs.

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.

AI Overview
An error occurred. Please try again.