NEMO® BY Progressing Cavity Pump
NEMO® Progressing Cavity Pumps

NEMO® BY Progressing Cavity Pump in Industrial Design

The solution to convey and accurately dose a wide range of media in various industries

The NEMO® BY progressing cavity pumps in industrial design is the standard progressing cavity pump model from NETZSCH for conveying and dosing complex media across various industries. This versatile pump design excels in applications in industries such as wastewater treatment, chemicals, mining, paper, biogas, other renewable energy, and the oil and gas upstream and mid/downstream sectors.

Whether conveying low to high-viscosity fluids or liquids that are shear-sensitive, abrasive that contain solids, the NEMO® BY progressing cavity pump ensures constant, low-pulsation and minimal shear conveyance with long service life. Its robust design allows it to handle variations in pressure and viscosity, making it a reliable choice for diverse and demanding applications.

Low Costs with the NEMO® BY Progressing Cavity Pump

In addition, the progressing cavity pump guarantees flow rates proportional to speed with high dosing accuracy over the entire speed range. In block design with flanged drive, this NEMO® progressing cavity pump is especially compact and economical.

 Moreover, the NEMO® BY progressing cavity pump is distinguished by its low investment, operating, and maintenance costs. Four Rotorrotor,Rotors,rotorsrotor/stator geometries are available for the various products and applications.

Please accept Marketing Cookies to see that Video.

Individual Consulting

Get a personalized offer!

contact now

Advantages Of NEMO® BY Progressing Cavity Pump 

The NEMO® BY progressing cavity pump in industrial design offers a range of advantages that make it a superior choice in fluid handling technology:

Optimal Solution for complex liquids
Conveys fluids with low to high viscosity, with or without solids, shear sensitive, abrasive and corrosive liquids.
Robust Construction

Engineered for robust, & compact block design for lasting performance in challenging environments
Effortless Maintenance

Designed for easy serviceability, reducing downtime and maintenance costs

NEMO® BY Progressing Cavity Pump Construction

The NEMO® BY progressing cavity pump is a standard design with a directly flanged closed coupled drive. It is compact in foot print, minimizing space requirements and simplifying installation. Built with only 30+ parts in total, the NEMO® BY progressing cavity pump ensures ease of assembly and disassembly, reducing downtime and maintenance efforts. The pump has four designs of Rotorrotor,Rotors,rotorsrotor and stator geometries, providing versatility to suit different flow and pressure demands with the smallest and most efficient pump for an application.

The NEMO® BY progressing cavity pump delivers robust performance across a wide range of operating conditions with its capability to deliver high flow rates and pressures. The NEMO® BY pump's lantern design features a single-size IEC flange, simplifying installation and alignment for the drive.

 The pump's shaft includes air release fluting, facilitating easy assembly and disassembly.  A single cross drilling per drive train allows for easy installation of the cross pin, which transmits torque while axial force is managed by an additional shoulder on the drive shaft. The pump's drive shaft is designed as one piece, enhancing its structural integrity and reliability. 

The NEMO® BY progressing cavity pump design offers mechanical seals suited to the product flow to minimize the risk of fiber wrap-around, sedimentation, or blocking. The various optional seal configurations provide flexibility to suit specific application requirements. The pump features a short lantern and drive shaft design, ensuring excellent concentricity and enhancing seal effectiveness and durability.

 The NEMO® BY pump's construction is designed to optimize performance, reliability, and ease of maintenance, making it a preferred choice for a wide range of industrial applications.

NEMO® pump with motor and HD-Stator® 2.0, designed for efficient fluid handling in industrial applications.
  • Models range from NM003 BY to NM148 BY, accommodating flow rates from 0.5 LPH to 300 m3/h
  • Differential pressures upto 24 Bar
  • Compact and block design
  • Ensures gentle conveyance of products.
  • Adaptable modular system for versatility.
  • Provides four rotor/stator geometries design and materials for diverse applications.
  • Mechanical seal with customizable seal designs and options.
  • Tailored joints to suit unique application requirements.
  • Excels in industrial applications across environmental technology, food, oil, and chemical industries.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM003 BY24up to0.00241,000
NM005 BY24up to0.0121,000
NM008 BY24up to0.11,000
NM011 BY24up to0.241,000
NM015 BY24up to2.5800
NM021 BY24up to3800
NM031 BY24up to5.5600
NM038 BY24up to18600
NM045 BY24up to20550
NM053 BY24up to30550
NM063 BY24up to40550
NM076 BY24up to60550
NM090 BY24490450
NM105 BY185150350
NM125 BY1210200350
NM148 BY820300250

Further sizes and technical data on request.

Two engineers discuss a technical document while inspecting a large industrial machine in a workshop setting.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BY Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.

FAQs

The NEMO® BY progressing cavity pump is versatile and can be used in wastewater treatment, chemicals, paper, biogas, battery, mining and the oil and gas upstream and mid/downstream sectors.

The NEMO® BY pump can handle complex media, that are low-high viscous fluids, shear-sensitive, abrasive, corrosive and solid-containing abrasive fluid materials.

The NEMO® BY progressive cavity pump models can accommodate flow rates from 0.0024 to 300 m³/h and are designed to handle pressures from 8 to 24 bar, depending on the specific model.

The NEMO® BY pump offers four rotor/stator geometries and materials for different applications. It is also equipped with a standard mechanical seal, with optional seals available for specific operational preferences, ensuring enhanced flexibility and customization. The pump is also available in designs suited for food industries that are compliant to EHEDG and 3A Designs.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Get in Touch for Expert Pump Advice

The NEMO® BY Progressing Cavity Pump in industrial design offers a comprehensive solution for many applications. Its innovative design easily conveys complex fluids, from low to high-viscosity liquids, and abrasive slurries while delivering exceptional efficiency and smooth operation. 

Contact our NEMO® BY progressing cavity Pump specialists today and discover how this innovative pump can optimize your fluid handling processes, maximize productivity, and minimize your down time.

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.