NEMO® BF Hopper Shaped Pump with Feeding Screw, NETZSCH, Pumps, Systems
NEMO® Progressing Cavity Pumps

NEMO® BF Hopper Pump with Force Feeding Screw

Pump Solution for Highly Viscous Dewatered Cakes and Sludge applications

The NEMO® BF Hopper Pump with a patented feed screw is particularly engineered and designed to handle highly viscous, non-flowing sludges that can tend to form bridges while being fed into a Pump. 

To ensure optimal product feed into the conveying elements, the NEMO® BF features an enlarged, rectangular feed hopper and a conical force-feed chamber. Additionally, it incorporates a special coupling rod with a patented, positioned conveying screw, enhancing the efficiency and reliability of the pump in demanding industrial applications.

The pump ensures smooth and continuous flow at pressure-stable, gentle, low-pulsation conveyance and precise, speed-proportional transfer of the sludge. It's robust construction and innovative design make it ideal for compacted and crumbly media applications like sludges/slurries conveying in wastewater treatment plants, mining, refineries, paper, and chemical industries.

 

NEMO® BF hopper with feeding screw pump ensures smooth conveying

This also ensures the smooth conveying of solids containing shear-sensitive, abrasive, adhesive, thixotropic or dilatant as well as lubricating and non-lubricating materials. The NEMO® BF is particularly compact and economical in block construction with flanged drive.

Please accept Marketing Cookies to see that Video.

Individual Consulting

Get a personalized offer!

contact now

Advantages of NEMO® BF Hopper Pump with Force Feeding Screw

Complex liquids handling 
Conveys highly viscous, non-newtonian sludges and liquids efficiently and reliably
Full Service in Place
The pump specific design offers FSIP®: Full service in place to ensure ease of maintenance and short replacement times.
Engineered Design
Pumps are adaptable and engineered to suit specific installation and process demands. Ensures compatibility with existing systems.

NEMO® BF Hopper Pump with Force Feeding Screw Construction

NEMO® BF Hopper Progressing Cavity Pump comes with an enlarged rectangular hopper along the conveying screw and conical force-feed chamber. The hopper dimensions can be adjusted to the individual application case based on installation and the nature of the liquid. 

The screw or auger with its patented design is welded on the coupling rod that transmits the rotary movement to the pumping elements. The design of this feeding screw is well suited to avoid wrapping of fibrous matter and ensure smooth feeding of the liquid into the pump conveying elements which are the Rotorrotor,Rotors,rotorsRotor and the Stator. 

The pump suction housing can be designed with materials in steel, chrome-nickel-steel, and stainless steel that can be coated for wear resistance. The NEMO® Pumping elements are designed to have a conical inlet to ensure smooth transfer of the sludge into the pumping elements.  The pumping elements are designed and selected for optimum lifetime for handling abrasive sludges.

The Pump shaft seals can be glad packing or single-acting, bi-directional seals to suit the process demands. 

The NEMO® BF pump's construction is designed to convey high viscous and crumbly media reliability, and for ease of maintenance, making it a preferred choice for a wide range of industrial applications.

Vertical screw pump with an electric motor, showcasing its robust design and internal spiral mechanism for fluid transport.
  • Flow rates up to 60 m³/h at pressures up to 36 bar in standard design.
  • Viscous and Non–flowable liquids and sludges conveyance with viscosity range up to 3 Million cP.
  • Excellent Elastomers for abrasion, chemical and thermal resistance.
  • Block Pump design with Closed Coupled Drive to ensure compact Installation.
  • Enlarged rectangular hopper for optimum feeding into the conveying elements. 
  • Block Design: Robust and compact block design best suited for compact installations.
  • Robust Joints: Various joint options are available to ensure optimal performance for complex applications when handling viscous and solids-containing liquids.
  • Seal Options: Standard mechanical seals are provided, with optional seals available for specialized needs.
  • Easy & Quick Maintenance: Designed for easy serviceability, reducing downtime and maintenance costs.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM045 BF360.24up to 120
NM053 BF360.29up to 120
NM063 BF360.214up to 120
NM076 BF360.224up to 120
NM090 BF360.238up to 120
NM105 BF360.260up to 120

Further sizes and technical data on request.

Two engineers discuss a technical document by a large industrial machine, indicating collaboration in a manufacturing setting.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BF Hopper Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up to date with the latest technology and performance standards.

FAQs

The NEMO® BF Hopper Shaped Pump is designed to handle complex media that are highly viscous, and crumbly materials that tend to bridge, abrasive and solids-containing media. The main purpose is to convey non–newtonian fluids.

The key design features include an enlarged rectangular feed hopper, a conical force-feed chamber, and a special coupling rod with a patented conveying screw. These elements ensure optimal product feed into the conveying elements and enhance the pump's efficiency and reliability.

The NEMO® BF Hopper Shaped Pump is ideal for handling dewatered sludges, and press cakes in wastewater treatment plants, and effluent treatment plants, that are output of dewatering equipment like filter presses, decanters, centrifuges and belt press. These are relevant chemical, petrochemical, paper and mineral processing industries. 

It is designed to handle challenging media, making it suitable for applications that require continuous, gentle, and pressure-stable conveying of highly viscous and crumbly substances.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Contact Us for Expert Solutions

Ready to optimize your industrial processes with the efficient and reliable NEMO® BF Hopper Design Pump with Feed Screw? Our team of experts provide personalized advice and solutions tailored to your specific needs.

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.

AI Overview
An error occurred. Please try again.