NEMO® BT Immersible Pumps With Bracket
NEMO® Progressing Cavity Pumps

NEMO® BT Immersible Vertical Pumps with Bracket or Flanges

Efficient Pump Solution for emptying Tanks, Sumps and Pits to transfer complex fluids

NEMO® BT Immersible Pumps

The NEMO® BT Immersible Pumps are vertically installed semi-submersible pumps, designed for efficient emptying and conveying of complex liquids from sumps, sedimentation tanks, pits, and similar vessels with liquid levels as deep as 12 mts. They excel in installations and applications where space is limited, and NPSH available is very low.

The Pumps are designed for several installation options and can be equipped with a bracket for crane suspension or mounted using sole plates for minimal vibration well within the tolerances. The pump design ensures continuous flow of sludge and has excellent wear resistant properties to handle solids content in the slurry.  The pumps can be used for emptying and conveying the fluids over long distances due to is pressure handling capability. The Pump design with its low vibration ensures smooth operation with long service life.

Individual Consulting

Get a personalized offer!

contact now

Advantages

Efficient Fluid emptying at Low NPSH
The pump ensures efficient and low-pulsation emptying or conveying of complex liquids from containers, sedimentation tanks, and pits under low NPSH conditions.
Flexible Mounting
With bracket or flange mounting options, the pump can easily adapt to various installation setups, providing flexibility in diverse applications.
Long service life
The pump is designed to operate effectively in low NPSH conditions, thus reduces the risk of cavitation, ensuring longer operational life and reliability.

NEMO® BT Immersible Pump Construction

The NEMO® BT Immersible Vertical Pump features a robust, compact design with a directly flanged drive. The pump can be suspended using a bracket or installed with, mounting plates to suit the installation offering installation flexibility. The pump features the classic NEMO® progressing cavity pump design with 4 helical rotors and stators combination, ensuring precise, low-pulsation fluid transport while maintaining a constant flow rate, even with varying viscosities and solids content.

The shaft seal which is along the fluid flow ensures constant flushing of the seal faces ensuring long seal life. The length of the pump can be customized to meet the specific needs of the application, and installation allowing for optimal vertical immersion in vessels with varying depths. The pump is equipped with various drive options, including direct drives or geared motors, to match the application’s flow rate and pressure requirements. The suction housing is designed for effective fluid entry into the Rotorrotor,Rotors,rotorsrotor-stator system, the suction housing ensures the smooth transport of fluids, even under low NPSH conditions, minimizing the risk of cavitation.

The pump can be installed at immersion depth up to 12 m, an additional support guide is available to secure the pump to the bottom or to the wall near the bottom. The pump can be easily removed from the full tank as the guide units are self-centering and secure the pump suction without fixings. The pump can be specifically designed to operate within the API 676 standards and within its vibration tolerances. This ensures the long service life of the pump.

High-efficiency vertical pump with a motor and helical impeller design, ideal for fluid transfer applications.

The NEMO® BT is engineered to handle a wide range of substances, including water and environmentally hazardous materials. It operates efficiently even in conditions with high sand content in the medium.

  • Flow Rates: Capable of delivering flow rates upto 140m3/hr
  • High Differential Pressures: Conveyance of fluids against pressures of up to 24 Bar.
  • Temperature Range: Suitable for use in temperatures up to 120°C (248°F).
  • Immersion depths upto 12 m

The pump’s high speed and precise dosing accuracy make it reliable for continuous operation.

  • Its vertical, semi-submersible construction allows for installation in confined spaces, making it ideal for tanks, pits, and other vessels where space is limited.
  • The pump’s immersible length can be adjusted to vessel depths, enhancing performance and versatility.
  • Constructed from high-quality, wear-resistant materials such as stainless steel or corrosion-resistant alloys, the pump ensures long-term durability and reliability, even with abrasive or corrosive fluids.
  • The robust construction, sealed shaft, and wear-resistant components reduce maintenance requirements, leading to less downtime and lower operating costs.
  • Suitable for a wide range of industries and media, from wastewater treatment to chemical and oil processing, the NEMO® BT pump is highly adaptable.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM021 BT24up to1,6up to 600
NM031 BT24up to5up to 600
NM038 BT24up to14up to 600
NM045 BT24up to24up to 600
NM053 BT24up to33up to 500
NM063 BT24up to52up to 450
NM076 BT24up to75up to 400
NM090 BT24up to110up to 350
NM105 BT24up to160up to 300
NM125 BT24up to240up to 250
NM148 BT24up to310up to 200

Further sizes and technical data on request.

Two engineers discussing technical drawings in a machine shop, with machinery and tools visible in the background.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BO/SO Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.

FAQs

The NEMO® BT Immersible Pumps are designed to handle viscous, abrasive, and solids-containing liquids, including water and environmentally hazardous substances, sedimented deposits, and mediums with high sand content. Their robust design ensures reliable performance even in challenging conditions. The liquids like Oily water, Sea water with solids, Wastewater and other abrasive liquids can be handled by the NEMO® BT Pump.

The NEMO® BT can be installed using a hanging bracket or dome cover flanges, allowing for flexible installation in various confined spaces, such as containers, sewage tanks, and pits.

Yes, the NEMO® BT Immersible Pumps are capable of operating under high conveying pressures upto 24 bar, making them suitable for applications requiring efficient and reliable high-pressure performance.

The modular design allows for easy customization and adaptability to specific application requirements. This ensures perfect dosing precision, proportional capacity adjustments, and efficient handling of various substances.

We offer comprehensive maintenance services, including routine and preventative maintenance, quick access to genuine spare parts, and prompt repair services. Our goal is to keep your pump in top condition and minimize downtime.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.

AI Overview