NEMO® SY Progressing Cavity Pump with Bearing Housing and Free Shaft End
Versatile, Reliable, and Engineered for the Most Demanding Industrial Applications
NEMO® SY design progressing cavity pumps are engineered for demanding applications across every industry for conveying fluids that are viscous with and without solids.
They efficiently run in speed-proportional to flow and offer continuous, pressure stable, gentle and low pulsation conveyance. This makes them globally trusted for their versatility and reliability.
These pumps are designed to handle a wide range of liquids, that are thin to viscous, solids-containing, shear-sensitive, lubricating and non-lubricating, thixotropic, dilatant, abrasive, and adhesive substances.
Ideally suited for a wide range of pressure applications, the NEMO® SY pumps can be customized with four Rotorrotor,Rotors,rotorsrotor/stator geometries designed to meet specific operational needs.
These pumps additionally come with bearing housing and free shaft end that allows compatibility with various drive types, such as servo motors, diesel engines, and hydraulic drives, making them highly adaptable for various industrial applications.
Advantages Of NEMO® SY Progressing Cavity Pump
NEMO® SY Progressing Cavity Pump Construction
The NEMO® Progressing Cavity Pump SY Design includes bearing housing and two-part shaft end in addition to the wetted assembly in the NEMO® BY progressing cavity pump model. The bearing housing allows dis-assembly of the wetted parts without dismantling the drive bearing.
The two-part shaft end allows all types of drive to be used universally and allows servicing the rotating parts simple and fast. Modification of BY to SY model and vice versa is possible, making it a versatile pump.

- Available in sizes NM 003 to NM148 with flow rates up to 500 m³/h
- Differential Pressures up to 72 bar (standard) or up to 240 bar (special applications)
- Two-piece shaft design and a new bearing housing
- Modular Construction: Variable and modular construction system enhances adaptability and customization.
- Versatile Geometries and Materials: Offers various rotor/stator geometries and a wide range of materials, catering to diverse fluid handling needs.
- Tailored Solutions: Provides the right joint for any application, ensuring precise and efficient fluid conveyance.
- Gentle Product Handling: Ensures gentle product conveyance, making it suitable for shear-sensitive materials.
- Sealing Options: Comes with a mechanical seal as standard, with the flexibility to opt for other sealing options as per requirements.
| Name | Pressure max. (bar) | Capacity min. (m³/h) | Capacity max. (m³/h) | Speed (rpm) |
|---|---|---|---|---|
| NM003 SY | 72 | up to | 0.003 | 1,000 |
| NM005 SY | 72 | up to | 0.015 | 1,000 |
| NM008 SY | 72 | up to | 0.1 | 1,000 |
| NM011 SY | 72 | up to | 0.2 | 1,000 |
| NM015 SY | 72 | up to | 2.5 | 800 |
| NM021 SY | 72 | up to | 3 | 800 |
| NM031 SY | 72 | up to | 5.4 | 600 |
| NM038 SY | 72 | up to | 18 | 600 |
| NM045 SY | 72 | up to | 20 | 550 |
| NM053 SY | 72 | up to | 31.5 | 550 |
| NM063 SY | 72 | up to | 38 | 550 |
| NM076 SY | 72 | 4 | 60 | 550 |
| NM090 SY | 60 | 5 | 88 | 450 |
| NM105 SY | 48 | 6 | 133 | 350 |
| NM125 SY | 36 | 20 | 130 | 350 |
| NM148 SY | 24 | 28 | 350 | 250 |
Further sizes and technical data on request.

Comprehensive Service and Support
At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® SY Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle.
- Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
- Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
- Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
- Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
- Modernization: We offer modernization services to keep your pump system up to date with the latest technology and performance standards.
FAQs
The NEMO® SY progressing cavity pumps are engineered for demanding applications across various industries, including environmental technology, food processing, oil and gas, and chemical processing.
These pumps are designed to handle a wide range of media, including thin to viscous liquids, fluids with solids content, shear-sensitive substances, lubricating and non-lubricating fluids, abrasive materials, and adhesive substances.
The inclusion of a bearing housing and free shaft end design allows for compatibility with different types of drives, such as servo motors, diesel engines, or hydraulic drives. This feature enhances the pumps' adaptability and makes servicing of rotating parts fast and efficient.
The NEMO® SY pumps can achieve flow rates of up to 500 m³/h and pressures of up to 48 bar (standard) or up to 240 bar for special applications, ensuring reliable performance even in demanding conditions.
The pumps are compliant to API 676 for Rotary Positive Displacement Pumps and are engineered for application standards in petrochemical industries and oil and gas mid and downstream processes. Special variants are offered formultiphase pumping applications.
Applications NEMO® SY with bearing housing
Get in Touch for Expert Pump Advice
Ready to optimize your industrial operations with our versatile NEMO® SY progressing cavity pumps? Contact our technical team today for personalized pump solutions tailored to your specific needs.
Don't hesitate—get in touch now to experience superior fluid handling technology with our NEMO® SY pumps.
FAQ progressing cavity pumps
Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.
NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.
Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.
Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.
Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.
The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.
All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.
The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.
The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.