NEMO® BH Mini Hygienic Progressing Cavity Pump, NETZSCH, Pumps, Systems
NEMO® Progressing Cavity Pumps

NEMO® BH Mini Hygienic Progressing Cavity Pump

The Ideal dosing pump for precise dosing in hygienic and sanitary applications

The NEMO® BH Mini Hygienic Progressive Cavity Pump is ideal for applications that demand high dosing accuracy in sanitary and hygienic applications, especially in the food, pharmaceutical, and cosmetics industries. 

This pump provides continuous, low-pulsation, and low-shear, liquid conveyance, making it ideal for critical processes in the food, cosmetics, pharmaceutical, chemical, and biochemical industries.

This hygienic pump is best suited in applications where high sanitary standards is critical. Its design features include FDA Certified Materials, compliant mechanical seals, and liquid contact areas that are free of dead space. The design is also able to address the cleaning-in-place needs.  

The primary area of application is to handle shear-sensitive, and thin to viscous media, with or without solids. The NEMO® BH Mini Pump guarantees high dosing accuracy, with less than one percent deviations, ensuring precise and reliable performance.

It is a compact close-coupled drive design pump. This design helps to install the pump in compact dosing skids. It can also be mounted according to the equipment or process design.

NEMO® BH Mini Hygienic Pump Meets Various Hygiene Standards

NEMO® BH Mini pumps are designed, manufactured, and tested to comply to the following standards:

  • FDA Compliance: Meets the stringent requirements of the Food and Drug Administration (FDA).
  • EU VO 1935/2004 Compliance: It conforms to the European Union regulations for materials intended to come into contact with food.
  • 3-A Sanitary Standard: Complies with the 3-A Sanitary Standards of the USA, guaranteeing high hygiene levels.

Please accept Marketing Cookies to see that Video.

Individual Consulting

Get a personalized offer!

contact now

Advantages of NEMO® BH Mini Hygienic Pump

Gentle Conveyance with Highest Dosing Accuracy 
The Pump ensures gentle handling of products, preserving their integrity/quality during conveyance.
 
Dosing accuracy can be achieved by up to +/-1%
Hygienic Design
All product-contacting surfaces are polished to prevent build-up and facilitate easy cleaning.
 
 The Pump seal is in the flow path ensuring constant flushing and no settlement in the seal area.
 
 Materials used are FDA Compliant 
Compact Design and Flexible Installation
The closed-coupled drive design makes the pump compact and easy to install in the systems.
 
 The pump design allows the capability to have reversible flow with same hydraulic performance

NEMO® BH Mini Hygienic Pump Construction

The NEMO® BH Mini hygienic Progressing Cavity Pump has pumping elements which are the Rotorrotor,Rotors,rotorsrotor made with compliant materials and finely polished surface and Stator which is an elastomer compliant to FDA Standards for sanitary applications.

The pump has a flexible rod that transfers power from the drive to the rotating part of the pumping elements.  It is corrosion-resistant, has no intermediate connections, and hence no crevices.

 The suction and discharge housings are of specific design to ensure smooth flow and avoid settling of the liquid medium in any dead spots or crevices. The surfaces are polished to meet the application demand. The end connections are with options to provide hygienic connections. The pump is also equipped CIP able construction.

The shaft seal is in the flow path of the liquid and is wetted and lubricated with the process liquid. The pump is equipped with food industry-compliant mechanical seals for reliability and safety.

The design of the pump is suited for reverse flow. The pump is ideal for viscous, shear-sensitive liquids and those with solids, ensuring high hygiene standards.

Centrifugal pump with a motor and a helical rotor design, ideal for fluid transfer in industrial applications.
  • NEMO® Mini Sizes are available in 003/005/008/011
  • Flow Rates: Capable of delivering flow rates from 0.1 LPH to 500 LPH from pressures of 2 to 36 bar.
  • Temperature Range: Suitable for use in temperatures up to 120°C
  • CIP Capability: Capable of Clean-in-Place (CIP), facilitating hygiene and thorough cleaning.
  • Flexible rod: Free of dead space for crevice-free transfer and no residues left, wear-, and maintenance-free rod.
  • Suction Capability: Capable of product admission under vacuum conditions up to, ensuring excellent priming and smooth conveyance without cavitation.
  • Installation Options: Can be installed horizontally and vertically, providing installation flexibility.
  • Optimal Media temperature management: The pump housing and stator can be optionally heated to maintain the appropriate temperature for the conveyed medium.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Operating rotational speed (rpm)
NM003 BH12up to0.00241,000
NM005 BH36up to0.0121,000
NM008 BH18up to0.051,000
NM011 BH12up to0.151,000

Further sizes and technical data on request.

Two engineers discuss specifications while reviewing a blueprint next to a large industrial machine in a workshop.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BH Mini Hygienic Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.

FAQs

The pumping elements in the progressing cavity design allows good flow control which is proportional to the rotation. This allows to achieve high dosing accuracy with only a 1% deviation. The pumps with gentle smooth continuous flow through the cavities ensure very low pulsation hence a better control of the dosing accuracy.

The pump meets strict regulatory standards, including FDA compliance, EU VO 1935/2004 conformity, and 3-A Sanitary Standards. These certifications ensure safety in hygienic applications.

This pump is best suited to draw liquids from vacuum conditions, due to its excellent self-priming capability.

The BH mini pump is designed for industries such as food, pharmaceuticals, cosmetics, chemicals, and biochemicals, where precise dosing and stringent hygiene standards are essential.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Contact Us for Expert Hygienic Pump Solutions

While faced with need or challenges in dosing complex fluids in sanitary applications we can offer the right design of NEMO® BH Mini Hygienic Pump. Our team of experts is here to provide personalized advice and solutions tailored to your specific needs.

Contact us and experience the precision, reliability, and efficiency of the NEMO® BH -Mini Hygienic Pump!

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.

AI Overview
An error occurred. Please try again.