NEMO® SH Plus Hygienic Pump With Bearing Housing, NETZSCH, Pumps, Systems
NEMO® Progressing Cavity Pumps

NEMO® SH Hygienic Plus Progressing Cavity Pump with Bearing Housing

Specialized Hygienic Pump Solution for Food, Pharma, Cosmetic, and Chemical Sectors with dead space free flexible rod

The NEMO® SH Plus Hygienic Progressing Cavity Pump with bearing housing is the ideal pump solution, specifically engineered for applications in the food, pharmaceutical, cosmetic, and chemical industries. These industries demand strict adherence to hygiene standards, making the NEMO® SH Plus ideal for maintaining cleanliness and ensuring optimal operational efficiency.

Designed for continuous, pressure-stable, gentle, and low-pulsation conveyance, the NEMO® SH Plus pump excels in dosing applications that require proportional speed adjustments. Its versatility and robust construction make it suitable for handling shear-sensitive, low to highly viscous, lubricating, non-lubricating, solid-laden, solids-free, thixotropic, dilatant, abrasive, or adhesive media.

The NEMO® SH Plus pump is distinguished by its hygienic design and optimal cleaning capabilities. It is capable of CIP (Clean-In-Place) and SIP (Sterilize-In-Place) processes, ensuring the highest levels of cleanliness and efficiency in demanding hygienic applications.

Integrating stringent hygiene standards, adaptable media handling, and reliable performance makes the NEMO® SH Plus Hygienic Pump with bearing housing an essential solution for industries that prioritize cleanliness and operational efficiency.

The NEMO® SH Plus Hygienic Pump complies with numerous hygiene standards.

NEMO® pumps are designed, manufactured, and tested to adhere to the following standards:

  • FDA Compliance: Meets the stringent requirements of the Food and Drug Administration (FDA).
  • EU VO 1935/2004 Compliance: It conforms to the European Union regulations for materials intended to come into contact with food.
  • 3-A Sanitary Standard: Complies with the 3-A Sanitary Standards of the USA, guaranteeing high hygiene levels.

Please accept Marketing Cookies to see that Video.

Individual Consulting

Get a personalized offer!

contact now

Advantages of NEMO® SH Plus Hygienic Pump

Complex liquids handling 
NEMO® SH Plus pump handles sanitary applications with media characteristics, like highly viscous, shear-sensitive, and solids-containing fluids without any loss of fluid characteristics.
Sanitary Design 
Streamlined, crevice-free housing model prevents product sedimentation, ensuring thorough cleanliness.
Easy Cleaning
All product-contacting surfaces are polished to prevent build-up of the medium and facilitate thorough cleaning, ensuring high hygiene standards and easy maintenance.

NEMO® SH Plus Hygienic Pump Construction

NEMO® SH Plus hygienic pump comes with a flexible rod to meet the high hygiene requirements, rather than open joints or joints filled with oil, that connects the drive to the shaft for handling highly sensitive, viscous, and abrasive liquids. The rod is heat-shrunk connected with the Rotorrotor,Rotors,rotorsrotor and connection point so that the liquid conveyance is hermetically sealed. 

Since there is no friction between components due to the connections/joints, there is hardly any wear on the flexible rod and it doesn’t need lubrication or seal, which reduces the maintenance costs. The material of construction used in sanitary applications is stainless steel of various grades – in a polished version for the wetted parts – and a stator made of FDA-compliant elastomer is used, and single-acting seals can be used for shaft seals, optionally also a double-acting seal can be provided. 

The pump design with bearing housing and drive shaft facilitates all types of drives ensuring versatility and flexible installation.

Advanced helical pump showcasing a sleek, metallic design, ideal for efficient fluid movement in industrial systems.
  • Flow rates from 1 LPH up to 140 m3/hr, ensuring efficient handling of complex fluids in food industries.
  • Excellent in dosing viscous fluids such as flavors and additives used in the process.
  • Excellent suction capability and hence suited for vacuum applications.
  • Conveyance of fluids against high differential pressures of up to 24 Bar.
  • Suitable for viscous liquids up to 1 to 3 Million cP, showing its capability for various types of fluid consistencies it can handle.
  • Capable of pumping high-viscous, abrasive liquids containing solid particles and shear-sensitive substances.
  • Flexible Rod Design: Designed for uncompromising hygiene and long service life, reducing maintenance frequency and costs.
  • FDA-Approved Elastomers: The shaft seal elastomers are approved for conveying complex liquids in the food industry by FDA standards, ensuring safety and compliance.
  • Installation Flexibility: Offers both horizontal and vertical installation options, providing adaptability for various setups.
  • Reversible Flow Direction The pump allows for a reversible direction of rotation, enabling conveyance in either direction up to the maximum pump pressure, providing operational flexibility.
  • Easy Serviceability: Designed for easy serviceability, reducing downtime, and ensuring consistent performance.
  • Optional Heating: The pump in a jacketed design can be optionally heated, making it suitable for handling temperature-sensitive media.
NamePressure max. (bar)Capacity min. (m³/h)Capacity max. (m³/h)Speed (rpm)
NM015 SH24up to0,7800
NM021 SH24up to2800
NM031 SH24up to5600
NM038 SH24up to12600
NM045 SH24up to20550
NM053 SH24up to30550
NM063 SH24up to40500
NM076 SH24up to55350
NM090 SH12up to80300
NM105 SH12up to120250

Further sizes and technical data on request.

Two engineers discuss plans by a machine in a workshop, highlighting collaboration in manufacturing processes.

Comprehensive Service and Support

At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® SH Plus Hygienic Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle. 

  • Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
  • Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
  • Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
  • Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
  • Modernization: We offer modernization services to keep your pump system up to date with the latest technology and performance standards.

FAQs

The pump features a hygienic design with polished surfaces and complies with FDA, EU-VO 1935/2004, and 3-A Sanitary Standards. It also supports CIP (Clean-In-Place) and SIP (Sterilize-In-Place) processes for optimal cleanliness.

This pump is suitable for conveying shear-sensitive, low to highly viscous, lubricating, non-lubricating, solid-laden, solids-free, thixotropic, dilatant, abrasive, or adhesive media.

The pump can achieve flow rates up to 140 m³/h and operate at pressures up to 24 bar, providing reliable performance under various conditions.

Yes, the pump can have optional heating and reversible flow direction. It can be mounted both horizontally and vertically, offering great flexibility for different applications.

Spare parts, documents, data

Discover MyNETZSCH, your digital customer portal.

Register for free now

Contact Us for Expert Hygienic Pump Solutions

Ready to enhance your sanitary applications with the NEMO® SH Plus Hygienic Progressing Cavity Pump? Our team of experts provide personalized advice and solutions tailored to your specific needs.

Your contacts and companies at NETZSCH

Any specific questions? Contact us for help or fill in the contact form.

FAQ progressing cavity pumps

Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.

NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.

Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.

Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.

NEMO® progressing cavity pumps are available in numerous designs, including block, hopper and hygienic versions. In addition, various materials, seal variants, and rotor-stator combinations are available to optimally adapt the pump to the respective application.

Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.

The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.

All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.

The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.

The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.

AI Overview
An error occurred. Please try again.