
NEMO® L.Cap® Progressing Cavity Pumps
Large Capacity Progressing Cavity Pumps for oil & gas, and mining industry.
The NEMO® L.Cap® Pumps by NETZSCH is a high-performance series of progressing cavity pumps designed to handle large volumes of fluids under low and high-pressure conditions, particularly in industries such as oil and gas and mining among others. These pumps are engineered to transport complex and challenging media, including, slurries, multiphase mixtures, high-viscosity fluids, and fluids with high solid content, over long distances with minimal wear and pulsation. The L.Cap® pumps provide efficient and reliable fluid handling, reducing operational costs and maintenance requirements while ensuring stable flow in some of the most demanding industrial environments.
The pump’s design is versatile, offering multiple versions, single and twin designs. In the twin configuration, the suction and discharge connections are equipped with manifolds, requiring only one inlet and one outlet process connection. Both pumps typically run simultaneously, though they can operate independently during maintenance.
The vertical version is particularly effective in tank applications, with a compact and highly efficient design. The single pump design can replace multiple centrifugal or piston pumps connected in series. The L.Cap® pump is ideal for oil and water emulsions, mine dewatering, or transferring mineral slurries. Regardless of the complexity of your requirements, the NEMO® L.Cap® offers optimal technology tailored to your application and working conditions.
Advantages of NEMO® L.Cap® Progressing Cavity Pump
Designed with low Net Positive Suction Head (NPSH) requirements, reducing the risk of cavitation and enabling more efficient operation even under low suction pressure conditions.
The robust construction with fewer wearing parts, reduces the frequency of maintenance and increases operational uptime.
NEMO® L.Cap® Progressing Cavity Pump Construction
The L.Cap® pumps use the progressing cavity pump principle, where a Rotorrotor,Rotors,rotorsrotor turns inside a stator to form cavities that move the medium. This design enables the pump to handle a wide range of viscosities, solids content, and multiphase fluids. The pump components, such as the rotor and stator, are made from highly durable materials to withstand abrasive fluids and media with high solid content. The pump design also complies with API 676 standards for flow and vibration tolerances, and NACE MR-0-175, which ensure corrosion resistance and long-term durability in oil, gas, and mining applications.
The L.Cap® twin version consists of two pumps mounted in parallel on a single base plate, sharing a common suction and discharge manifold. This construction allows both pumps to operate simultaneously or individually during maintenance. In contrast, the single version is designed for moderate flow and pressure applications with a simpler configuration but similar robustness. There is also a vertical design option available, primarily for in-tank applications.
A compact and efficient pump design for tank applications. Special design considerations have been made to protect the pump from dry running, ensuring long-term durability. The pumps are mounted on a heavy-duty base plate, which allows for stable installation and ease of maintenance. This also contributes to operational safety and reliability, particularly in high-pressure environments.
The robust pump meets the highest safety standards, conforming to API 676 3rd edition and NACE MR-0-175.

NEMO® L.Cap® progressing cavity pumps are highly suitable for applications that require the movement of large fluid volumes under significant pressure, such as crude oil transfer and mine dewatering.
- Flow Rates: Up to 1000 m³/hr
- Pressure Range: Up to 20 bar
- Efficiently handle multiphase mixtures (oil, water, and gas) as well as fluids with high solid content, such as drilling sludge, slurries, and mineral slurries.
- Stable, near pulsation-free flow
- Stable and Pulsation-Free Flow: Ensures smooth, almost pulsation-free flow. This results in a more consistent and reliable pumping process, which is crucial for maintaining stable operations in industrial operations
- Handling of Multiphase Fluids: Capable of handling multiphase liquids, including oil, gas, and water mixtures that contain solids.
- Low Shear and Gentle Handling: The pump design minimizes shear forces on the fluid, preserving the integrity of the pumped medium, which is essential when dealing with delicate or highly viscous fluids.
- Low operational costs: Due to their stable flow, low operating and maintenance costs, and fewer wearing parts, L.Cap® pumps offer long-term cost efficiency. Additionally, in applications requiring high flow and pressure, they can replace multiple centrifugal or piston pumps, reducing complexity and associated costs.
| Name | Pressure max. (bar) | Capacity max. (m³/h) | Speed (rpm) |
|---|---|---|---|
| Single version | 24 | 400 | 250 |
| Twin version | 20 | 1000 | 250 |
Further sizes and technical data on request.

Comprehensive Service and Support
At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® L.Cap® Progressing Cavity Pump systems. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle.
- Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
- Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
- Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
- Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
- Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.
FAQs
The NEMO® L.Cap® Pumps can handle high flow rates and high pressures, efficiently transporting oil, gas, and water mixtures with high solids content.
Its efficient design ensures minimal maintenance and high reliability, reducing downtime and operational costs.
Applications NEMO® L.Cap progressing cavity pump
Get in Touch for Expert Pump Advice
Discover the efficiency and reliability of our NEMO® L.Cap® Progressing Cavity Pumps. Contact our technical team today to discuss your fluid handling needs and learn how our customizable pump solutions can optimize your operations.
We offer consultation, technical support, and help in selecting the right pump for your application. Contact us now to start maximizing productivity and minimizing costs with our innovative pumping solutions.
FAQ progressing cavity pumps
Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.
NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.
Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.
Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.
Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.
The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.
All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.
The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.
The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.










