
NEMO® BO/SO Hopper Pump With Cutting Device
Hopper Pump with cutting and conveying elements for pumping large particles, especially in the food industry
The NEMO® BO/SO hopper pump with integrated cutting device seamlessly combines the cutting and conveying of large particles. Designed to streamline processes and eliminate the need for costly additional equipment, this innovative pump offers efficient cutting and conveying in a single process step and can be an ideal pump solution for the food industry.
With its integrated cutting device, the NEMO® BO/SO pump can handle a wide range of applications across various sectors for liquids with a viscosity of about 5000 cP. In food processing, the pump excels at chopping and pumping large solids in applications like conveying watery vegetables and prepares them for further processing with ease and speed.
At the heart of the NEMO® BO/SO progressing cavity pump is its progressing cavity technology, which ensures continuous, pressure-stable, gentle, and low-pulsation conveyance.
The NEMO® BO/SO Hopper Pump with cutting device efficiently manages viscous to non-free-flowing media, whether containing solids or not, making it a reliable pump solution in a wide range of industrial processes.
NEMO® BO/SO: Two process steps with only one pump
Optionally the pump can be equipped with an additional cutting unit at the discharge flange of the pump. With its perforated disc and rotating knife, it allows for further fine definition of the particle size.
As with any other NEMO®progressing cavity pump also the BO/SO pump has the ability to dose the conveyed media in proportion to rotation speed. In block construction with a flanged drive, this pump is particularly compact and economical in addition, the NEMO® is characterized by low investment, operating, and maintenance costs.
However, it is also available in bearing block design with a free shaft end. This means that the pump can be operated with different types of drive, such as servo motors, diesel engines, or hydraulic drives.
Advantages of NEMO® BO/SO Hopper Pump With Cutting Device
NEMO® BO/SO Hopper Pump With Cutting Device Construction
The NEMO® BO/SO progressing cavity pump is designed with a hopper to enable ease of production flow in the suction, the coupling rod with a feeding screw, and a set of cutters in force-feed chamber to provide continuous, pressure-stable, gentle, and low-pulsation cutting and conveyance.
The hopper housing with a cutting unit guarantees an optimum size reduction of chunky solids into the pump conveying elements. The larger fruits and vegetables are cut immediately once the medium passes the force-feed/compression chamber with the cutting device.
This unit consists of a rotating knife with three blades and a variable number of stationary knives adjustable to the size and consistency of the particles. Optionally the pump can be equipped with an additional cutting unit at the discharge flange of the pump. With its perforated disc and rotating knife, it allows for further fine definition of the particle size.
This special version of a NEMO® BO/SO hopper pump with cutting device has been designed for applications in the food industry.

- Flow rates from 1 LPH up to 200m3/hr, ensuring efficient conveying of highly viscous, complex fluids with solid particles and shear-sensitive liquids in food industries.
- Conveyance of fluids against high differential pressures of up to 24 Bar.
- Suitable for viscous liquids up to 1 to 3 Million cP
- Enhanced Product Feeding: Equipped with a feed hopper and compression chamber to improve product feeding efficiency.
- Optional Additional Cutting Unit: Features an additional cutting unit at the discharge flange for finer particle size control.
- Compact and Economical Design: Offers a compact, flanged drive construction to reduce investment and maintenance costs.
- Robust and Compact Construction Designed for cutting and conveying ensures durability and efficiency, ensuring long-term reliable operation.
- Linear Flow: Delivers consistent conveyance volume proportional to rotation speed across a broad range for flow and pressure.
- Modular System: Allows optimal conveyance and cutting customized to the applications in Food industry.

Comprehensive Service and Support
At NETZSCH, our commitment to your success extends well beyond the initial purchase of your NEMO® BO/SO Progressing Cavity Pump. We offer a complete range of aftermarket services to ensure your pump operates at peak efficiency and reliability throughout its lifecycle.
- Consultation: Our experts provide tailored advice to help you select the right pump configuration and optimize your processes.
- Spare Parts: We maintain a full inventory of genuine spare parts to minimize downtime and ensure optimal pump performance.
- Maintenance: Our routine and preventative services keep your pump running smoothly and prevent unexpected breakdowns.
- Repair: Swift and Efficient: Our prompt repair services ensure minimal disruption and a quick return to operation.
- Modernization: We offer modernization services to keep your pump system up-to-date with the latest technology and performance standards.
FAQs
The NEMO® BO/SO design is a Hopper Pump for ease of feeding viscous liquids and it integrates cutting and conveying function, eliminating the need for separate equipment and reducing the investment costs in the food industry.
The food Industry, especially vegetable processing and fruit pulp industries can benefit from the innovative design with cutting device, versatility, and efficiency of the NEMO® BO/SO Hopper Pump.
The pump can deliver flow rates up to 200 m³/h and operate at pressures up to 24 bar, ensuring reliable performance in various industrial settings.
This pump can efficiently handle highly viscous, non-free flowing, and solids-containing media, like fruit and vegetable pieces, making it suitable for food applications.
Yes, the pump features robust construction and ease of service, simplifying maintenance procedures and reducing downtime.
Applications NEMO® BO/SO pump with cutting device
Contact Us for Expert Solutions
Ready to enhance your food processing applications with the NEMO® BO/SO Hopper Pump with a cutting device? Our team of technical experts provide personalized advice and solutions tailored to your specific needs.
FAQ progressing cavity pumps
Progressing cavity pumps are particularly suitable for pumping highly viscous, abrasive, solid-laden or shear-sensitive media. Typical applications include the chemical, food, environmental, paper and building materials industries, as well as the oil and gas sector.
NEMO® progressing cavity pumps from NETZSCH Pumps & Systems are characterised by gentle, low-pulsation pumping, high dosing accuracy and a wide range of applications. They enable a constant delivery rate even with changing pressures and media compositions.
Progressing cavity pumps can be used to convey low-viscosity to highly viscous media, including slurries, suspensions, pastes, media with a high solids content, and sensitive or gas-laden liquids.
Yes, progressing-cavity pumps are self-priming and exhibit excellent suction performance. This makes them ideal for applications with changing fill levels or difficult suction conditions.
Maintenance requirements are low and predictable. Wear parts such as the rotor and stator can be easily replaced. Maintenance-friendly designs enable short downtimes and high plant availability.
The service life depends on factors such as the medium, speed, pressure and choice of materials. Professional design and the use of original spare parts ensure a long service life and economical operation.
All relevant original spare parts are available for progressing cavity pumps from NETZSCH Pumps & Systems, including rotors, stators, seals, joint parts and other wear-related components. The spare parts are precisely matched to the pump design and ensure high operational reliability.
The correct spare part can be identified by the machine number, serial number, or item number. Spare parts lists, sectional drawings and the operating and maintenance instructions also provide support. Alternatively, the NETZSCH Pumps & Systems service team can provide expert advice on selecting the right original spare part.
The experts at NETZSCH Pumps & Systems will assist you in the design, selection and integration of the right progressing cavity pump – tailored to your specific pumping tasks and process requirements.











